D-Link DES-7210-BASE Quick Installation Guide - Page 4

Total Power

Page 4 highlights

Note: All grounding conductors should be connected before, and disconnected after the line and neutral(AC)/ input(DC) conductors. - A minimum of 10mm² (6AWG) of conductive grounding should be provided to the equipment grounding terminals on the rear panel. - For power supply unit 7200-2000DC, a minimum 10mm² (6AWG) of conductive grounding should be provided to the input terminal. - For power supply unit 7200-1200DC, a minimum 4mm² (10AWG) of conductive grounding should be provided to the input terminal. - For power supply unit 7200-2000AC and 7200-1200AC, a minimum 2.5mm² (12AWG) of conductive grounding should be provided to the input terminal. Power Requirements When DES-7200 uses the AC power supply: 7200-1200AC Rated voltage: 100-240VAC, 50/60Hz Tolerance range: 90-264VAC, 47-63Hz Total power: 1200W 7200-2000AC Rated voltage: 100-240VAC, 50/60Hz Tolerance range: 90-176VAC, 47-53Hz 1200W 176-264VAC, 57-63Hz 2000W Total power: 2000W When DES-7200 uses the DC power supply: 7200-1200DC Rated voltage: -48VDC Tolerance range:8&%Ŧ8&% Total Power: 1200W 7200-2000DC Rated voltage: -48VDC Tolerance range:8&%Ŧ8&% Total Power: 2000W DES-7200 Series Modules 7200-CM1 7200-CM2 7200-CM3 7200-CM4 7200-24G 7200-24 7200-48 7200-24GE 7200-2XG Maximum Power Consumption (W) 30 30 50 50 75 85 100 75 75 7200-4XG 100 7200-24P 7200-48P 7200-ASE3 85+15.4*N (N indicates the PoE port being used, of which the value is less than 24) 100+15.4*N (N indicates the PoE port being used, of which the value is less than 48) 100 Table 2. Power Requirements Note: The DES-7200 provides 1+1 power supply redundancy. D-Link recommends the use of multiple power supplies for the equipment to ensure continuous and stable operation. Redundant power helps to prevent unexpected equipment power failures. Redundant power supplies must be identical. 4 ‹ D-Link 6/10 Slot Chassis-Based Switch

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11

4
D-Link 6/10 Slot Chassis-Based Switch
Power Requirements
When DES-7200 uses the AC power supply:
7200-1200AC
Rated voltage:
100-240VAC, 50/60Hz
Tolerance range:
90-264VAC, 47-63Hz
Total power:
1200W
7200-2000AC
Rated voltage:
100-240VAC, 50/60Hz
Tolerance range:
90-176VAC, 47-53Hz
1200W
176-264VAC, 57-63Hz
2000W
Total power:
2000W
When DES-7200 uses the DC power supply:
7200-1200DC
Rated voltage:
-48VDC
Tolerance range:
Total Power:
1200W
7200-2000DC
Rated voltage:
-48VDC
Tolerance range:
Total Power:
2000W
DES-7200 Series
Modules
Maximum Power
Consumption (W)
7200-CM1
30
7200-CM2
30
7200-CM3
50
7200-CM4
50
7200-24G
75
7200-24
85
7200-48
100
7200-24GE
75
7200-2XG
75
7200-4XG
100
7200-24P
85+15.4*N
(N indicates the PoE port being
used, of which the value is less
than 24)
7200-48P
100+15.4*N
(N indicates the PoE port being
used, of which the value is less
than 48)
7200-ASE3
100
Table 2. Power Requirements
Note:
All grounding conductors should
be connected before, and discon-
nected after the line and neutral(AC)/
input(DC) conductors.
A minimum of 10mm² (6AWG) of
-
conductive grounding should be
provided to the equipment grounding
terminals on the rear panel.
For power supply unit 7200-2000DC,
-
a minimum 10mm² (6AWG) of
conductive grounding should be
provided to the input terminal.
For power supply unit 7200-1200DC,
-
a minimum 4mm² (10AWG) of
conductive grounding should be
provided to the input terminal.
For power supply unit 7200-2000AC
-
and 7200-1200AC, a minimum
2.5mm² (12AWG) of conductive
grounding should be provided to the
input terminal.
Note:
The DES-7200 provides 1+1
power supply redundancy. D-Link
recommends the use of multiple
power supplies for the equipment
to ensure continuous and stable
operation. Redundant power helps to
prevent unexpected equipment power
failures. Redundant power supplies
must be identical.