Canon LX-MU700 User Manual - Page 3

Projector Installation Notice, Verify Installation Location, Cooling notes, Power Safety, Air outlet

Page 3 highlights

♦♦ Projector Installation Notice ■■ Place the projector in a horizontal position If installing the projector on the floor or hanging from the ceiling, the left /right inclination of the projector should be no more than 10 degrees. An inclination of more than 10 degrees may damage the lamp. ■■ Allow at least 70 cm clearance around the exhaust vent. ■■ Ensure that the intake vents do not recycle hot air from the exhaust vent. ■■ When operating the projector in an enclosed space, ensure that the surrounding air temperature within the enclosure does not exceed operation temperature while the projector is running, and the air intake and exhaust vents are unobstructed. ♦♦ Verify Installation Location ■■ Turn on Altitude Mode when located in high altitude areas. ■■ The projector can only be installed upright or inverted. ■■ When installation the bracket, make sure the weight limit is not exceed and firmly secured. ■■ Avoid installing at high temperature, insufficient cooling and heavy dust locations. ■■ Keep your product away from fluorescent lamps to avoid malfunction caused by IR interference. ■■ The VGA IN connector should be connected to the VGA IN port. Note that it should be inserted tightly, with the screws on both sides securely fastened to ensure proper connection of the signal wire for achieving optimal display effect. ■■ The power cord and signal cable should be connected before power on the projector. During the projector starting and operating process, DO NOT insert or remove the signal cable or the power cord to avoid damaging the projector. ♦♦ Cooling notes Air outlet ■■ Air outlet location should not be in front of the lens of other projector to avoid causing illusions. ■■ Keep the outlet at least 70 cm away from the inlets of other projectors. ■■ The projector generates a massive amount of heat during use. The internal fan dissipates the heat of the projector when shutting down, and such process may continue for a certain period. After the project enters STANDBY MODE status, press the AC power button to turn off the projector and remove the power cord. DO NOT remove the power cord during the shutdown process, as it may cause damage to the projector. In the meantime, the delayed heat radiating will also affect the service life of the projector. The shutdown process may vary depending on the model used. Whatever the case may be, be sure to disconnect the power cord till after the projector enters the STANDBY status. Air inlet ■■ Make sure there is no object blocking air input within 50 cm. ■■ Keep the inlet away from other heat sources. ■■ Avoided heavy dust area. ♦♦ Power Safety ■■ Only use the supplied power cord. ■■ Do not place anything on the power cord. Place the power cord where it will not be in the way of foot traffic. ■■ Remove the batteries from the remote control when storing or not in use for a prolonged period. ■■ The wall outlet must be able to meet the power demands of the device. ii

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90

ii
Projector Installation Notice
Place the projector in a horizontal position
If installing the projector on the floor or hanging from the ceiling, the left /right inclination of the
projector should be no more than 10 degrees. An inclination of more than 10 degrees may damage
the lamp.
Allow at least 70 cm clearance around the exhaust vent.
Ensure that the intake vents do not recycle hot air from the exhaust vent.
When operating the projector in an enclosed space, ensure that the surrounding air temperature
within the enclosure does not exceed operation temperature while the projector is running, and the
air intake and exhaust vents are unobstructed.
Verify Installation Location
Turn on Altitude Mode when located in high altitude areas.
The projector can only be installed upright or inverted.
When installation the bracket, make sure the weight limit is not exceed and firmly secured.
Avoid installing at high temperature, insufficient cooling and heavy dust locations.
Keep your product away from fluorescent lamps to avoid malfunction caused by IR interference.
The VGA IN connector should be connected to the VGA IN port. Note that it should be inserted
tightly, with the screws on both sides securely fastened to ensure proper connection of the signal
wire for achieving optimal display effect.
The power cord and signal cable should be connected before power on the projector. During the
projector starting and operating process, DO NOT insert or remove the signal cable or the power
cord to avoid damaging the projector.
Cooling notes
Air outlet
Air outlet location should not be in front of the lens of other projector to avoid causing illusions.
Keep the outlet at least 70 cm away from the inlets of other projectors.
The projector generates a massive amount of heat during use. The internal fan dissipates the heat
of the projector when shutting down, and such process may continue for a certain period. After
the project enters STANDBY MODE status, press the AC power button to turn off the projector
and remove the power cord. DO NOT remove the power cord during the shutdown process, as it
may cause damage to the projector. In the meantime, the delayed heat radiating will also affect
the service life of the projector. The shutdown process may vary depending on the model used.
Whatever the case may be, be sure to disconnect the power cord till after the projector enters the
STANDBY status.
Air inlet
Make sure there is no object blocking air input within 50 cm.
Keep the inlet away from other heat sources.
Avoided heavy dust area.
Power Safety
Only use the supplied power cord.
Do not place anything on the power cord. Place the power cord where it will not be in the way of
foot traffic.
Remove the batteries from the remote control when storing or not in use for a prolonged period.
The wall outlet must be able to meet the power demands of the device.