LV-7290 / LV-7295 / LV-7390/ LV-8225 Expand Serial Command Functional Specifications 9.5 PC Adjust Status Read Command 9.5.1 CR_FSYNC Command Command "CR_FSYNC"[CR] Details Get Fine Sync value Acceptable "000_%a"[CR] Response %a "0000"~"0031" Unacceptable "Error Code"[CR] 9.5.2 CR_TDOTS Command Command "CR_TDOTS"[CR] Details Get Total Dots value Acceptable "000_%a"[CR] "nnnn"~"mmmm" Response %a (nnnn = Display Dots + Horizontal Position) (mmmm= Maximum value depends on input signal) Unacceptable "Error Code"[CR] 9.5.3 CR_CLAMP Command Command "CR_CLAMP"[CR] Details Get Clamp value Acceptable "000_%a"[CR] Response %a "0001"~"nnnn" ("nnnn" depends on input signal) Unacceptable "Error Code"[CR] 9.5.4 CR_H - POS Command Command "CR_H - POS"[CR] Details Get Horizontal Position value Acceptable "000_%a"[CR] Response %a "0000"~"nnnn" (nnnn = Total Dots - Display Dots) Unacceptable "Error Code"[CR] 9.5.5 CR_V - POS Command Command "CR_V - POS"[CR] Details Get Vertical Position value Acceptable "000_%a"[CR] Response %a "0000"~"nnnn" (nnnn = Total Line - Display Line) Unacceptable "Error Code"[CR] 53