Yamaha M7CL M7cl V2 Editor Owner's Manual - Page 28
DYNAMICS1/2, ATT Attenuation, LIBRARY, Response curve, GR meter, THRESHOLD Threshold level, RANGE
View all Yamaha M7CL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
K ATT (Attenuation) Adjusts the amount of attenuation/gain. ❏ DYNAMICS1/2 You can select one of the following types for each of the two dynamics processors. DYNAMICS1: GATE, DUCKING, EXPANDER, COMPRESSOR DYNAMICS2: COMPRESSOR, COMPANDER-H, COMPANDER-S, DE-ESSER If GATE/DUCKING is selected 51 4 2 3 6 7 8 9 J K L M A TYPE Indicates the type of the currently selected gate. You can click here to select the type. B LIBRARY This button accesses the dynamics library. Clicking this button will open the DYNAMICS page of the LIBRARY window. C ON This button switches the gate on/off. D Response curve Indicates the response for the gate of the currently selected channel. E GR meter This meter indicates the amount of gain reduction. F THRESHOLD (Threshold level) Specifies the level at which the gate will open and close. The gate will open when the key-in signal exceeds this level, and will close when the signal falls below this level. G RANGE Specifies the amount by which the signal is attenuated while the gate is closed. H DECAY Specifies the time over which the gate will close after the hold time has elapsed. I ATTACK Specifies the time from when the key-in signal exceeds the threshold level until the gate opens. 28 M7CL V2 Editor Owner's Manual