Viking VGR7362 Natural Gas Conversion Kit - NKVGR - Installation Instructions - Page 4

Surface Burner Ori, ce Locations, Surface Burner Ori, Front Surface Burner Conversion, Rear Surface

Page 4 highlights

Surface Burner Conversion Preparing for Top Surface Conversion Remove all grates, grate supports, surface burner caps, and griddle NOTE: Some models may not be equipped with all parts mentioned above. IMPORTANT: For models equipped with griddles, notice position of griddle temperature probe for proper reinstallation. Failure to properly reinstall could result in damage to griddle temperature probe. Front Surface Burner Conversion -Locate bag labeled 050300-000 -Remove screws (Item #1) with a T-20 Torx bit. -Remove venturi flange (Item #2). -Use a metric 10mm nut driver to remove orifice (Item #3). -Replace orifice with #44 from 050300-000 bag. The orifice Top View of will have a violet color code ink and 086 stamped on the Venturi flange orifice. Tech tip: Tape can be applied to the inside of the socked to assist in the removal of the surface burne orifices. This can prevent the orifices from falling into the range during removal. Burner Head Item #1 Item #2 -After replacing the orifice, replace Item#2 venturi flange with Natural venturi flange labeled 050576-000. Note orientation of venturi flange (refer to Top view of Venturi flange). -Reinstall screws and reverse procedure to reassemble. Front of unit Item #3 NOTE: For proper placement of the burner head, rotate until burner head seats into groove. Rear Surface Burner Conversion -Locate bag labeled 050300-000 -Remove screws (Item #1) with a T-20 Torx bit. -Remove venturi flange (Item #2). -Use a metric 10mm nut driver to remove orifice (Item #3). -Replace left rear orifice with .048" from 050300-000 bag. The orifice will have a dark green color code ink and 048 stamped on the orifice. -Replace all other rear orifices with #51 from 050300-000 bag. The orifice will have a yellow color code ink and 067 stamped on the orifice. Top View of Venturi flange Tech tip: Tape can be applied to the inside of the socked to assist in the removal of the surface burner orifices. This can prevent the orifices from falling into the range during removal. -After replacing the orifice, reinstall the current Item#2 venturi flange (it will not be replaced). Note orientation of venturi flange (refer to Top view of Venturi flange). -Reinstall screws and reverse procedure to reassemble. Front of unit Burner Head Item #1 Item #2 Item #3 NOTE: For proper placement of the burner head, rotate until burner head seats into groove. 6 Surface Burner Conversion 36" Surface Burner Orifice Locations C B* B (*Not applicable on griddle models) Burner A Burner B Burner C #44 (2.18 mm) #51 (1.70 mm) .048" (1.22 mm) A A* A (*Not applicable on griddle models) 48" Surface Burner Orifice Locations C B B* B (*Not applicable on griddle models) Burner A Burner B Burner C #44 (2.18 mm) #51 (1.70 mm) .048 (.1.22 mm) A A 7 A* A (*Not applicable on griddle models)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

6
7
Surface Burner Conversion
A
A*
A
B
B*
C
Burner A
#44 (2.18 mm)
Burner B
#51 (1.70 mm)
Burner C
.048” (1.22 mm)
36” Surface Burner Ori
ce Locations
A
A
B
C
Burner A
#44 (2.18 mm)
Burner B
#51 (1.70 mm)
Burner C
.048 (.1.22 mm)
48” Surface Burner Ori
ce Locations
A
B
Surface Burner Conversion
Front Surface Burner Conversion
Item #1
Item #2
Item #3
Front of unit
Top View of
Venturi flange
Burner
Head
-Locate bag labeled 050300-000
-Remove screws (Item #1) with a T-20 Torx bit.
-Remove venturi flange (Item #2).
-Use a metric 10mm nut driver to remove orifice (Item #3).
-Replace orifice with #44 from 050300-000 bag. The orifice
will have a violet color code ink and 086 stamped on the
orifice.
Tech tip:
Tape can be applied to the inside of the socked
to assist in the removal of the surface burne
orifices.
This can prevent the orifices from falling
into the range during removal.
-After replacing the orifice, replace Item#2 venturi flange
with Natural venturi flange labeled 050576-000.
Note
orientation of venturi flange (refer to Top view of Venturi
flange).
-Reinstall screws and reverse procedure to reassemble.
NOTE:
For proper placement of the burner head, rotate until burner head seats into groove.
Rear Surface Burner Conversion
Item #1
Item #2
Item #3
Front of unit
Top View of
Venturi flange
Burner
Head
-Locate bag labeled 050300-000
-Remove screws (Item #1) with a T-20 Torx bit.
-Remove venturi flange (Item #2).
-Use a metric 10mm nut driver to remove orifice (Item #3).
-Replace left rear orifice with .048” from 050300-000 bag.
The orifice will have a dark green color code ink and 048
stamped on the orifice.
-Replace all other rear orifices with #51 from 050300-000
bag. The orifice will have a yellow color code ink and 067
stamped on the orifice.
Tech tip:
Tape can be applied to the inside of the socked
to assist in the removal of the surface burner
orifices.
This can prevent the orifices from falling
into the range during removal.
-After replacing the orifice, reinstall the current Item#2
venturi flange (it will not be replaced).
Note orientation of
venturi flange (refer to Top view of Venturi flange).
-Reinstall screws and reverse procedure to reassemble.
NOTE:
For proper placement of the burner head, rotate until burner head seats into groove.
(*Not applicable on
griddle models)
(*Not applicable on
griddle models)
B*
A*
(*Not applicable on
griddle models)
(*Not applicable on
griddle models)
Preparing for Top Surface Conversion
Remove all grates, grate supports, surface burner caps, and griddle
NOTE: Some models may not be equipped with all parts mentioned above.
IMPORTANT:
For models equipped with griddles, notice position of griddle temperature probe for proper reinstallation.
Failure to properly reinstall could result in damage to griddle temperature probe.