Viking RVDR330 Natural Gas Conversion Kit - RDNKR3 - Installation Instructions

Viking RVDR330 Manual

Viking RVDR330 manual content summary:

  • 1
  • 2
  • 3
  • 4

The pressure regulator and the burner orifices are set for LP gas.
To use natural gas, the regulator and burner orifices must be
converted.
To convert the range to NAT gas, follow these instructions:
1.
Disconnect all electrical power at the main circuit breaker or
fuse box.
2.
Shut off the gas supply to the range by closing the manual
shut-off valve.
Converting the Pressure Regulator
1.
Locate the pressure regulator which can be found on the back
of the range on the right hand side if facing the back of the
range.
2.
Unscrew the hex nut cap from the top of the regulator.
3.
Unsnap the plastic plunger from the hex nut.
4.
Reverse the plunger and reinstall onto the hex nut by
pressing firmly.
Note:
Plunger is marked “Nat” and “LP”. Converted fuel type will
be shown on the lower portion of the plunger.
Converting the Surface Burners
1.
Remove the top grates, burner caps, and burner heads.
2.
Using a 9/32” or 7 mm nut driver remove the top burner
orifices. These may be accessed through the opening in the
burner base.
Note:
Save these orifices for future conversion back to NAT gas, if
required.
3.
Locate the proper NAT surface
burner orifices included with
the kit according to the chart
below.
4.
Install the orifices in their
correct location. To prevent leakage, make sure the orifice
spuds are securely screwed into the burner base.
WARNING
The conversion must be performed by a qualified
installer or gas supplier in accordance with the
manufacturer’s instructions and all codes and
requirements of the authority having jurisdiction. Failure to
follow
ALL
instructions could result in serious injury or
property damage. The qualified agency performing this
work assumes responsibility for this conversion.
Natural
LP
NAT
LP
NAT
LP
Apply sideways
finger pressure
to remove pin
from cap
Orifice
spud
Burner
cap
Burner
grate
Burner
head
Burner
base
Orifice
size
0.79
Orifice
Burner
BTU Rate
Orifice Size
Left front (dual)
High
Low
18,000
1,400
2.17
0.71
Left rear
8,000
1.32
Center
9,000
1.40
Right front
17,000
1.98
Right rear
12,000
1.61
Bake
30,000
#38 (
2.58
)
Broil
15,000
#50 (
1.87
)
NAT Conversion Kit Instructions for D3 / 300 Series
Gas Self Clean and Dual Fuel Range
1.32
2.17
0.71
1.98
1.40
1.61
Burner
BTU Rate
Orifice Size
Left front
18,000
1.98
Left rear
8,000
1.32
Center
9,000
1.40
Right front
17,000
1.98
Right rear
12,000
1.61
Bake
30,000
#38 (
2.58
)
Broil
15,000
#50 (
1.87
)
1.32
1.98
1.98
1.40
1.61
D3
300 Series