B. Optional function Get Function Length ID Command Type (ASCII) Command Response Range Code (ASCII) Code (Hex) (Three ASCII bytes) Comments Get-Contrast 8 Get-Sharp- 8 ness Get-Color 8 g a 61 000 ~ 100 g c 63 000 ~ 100 g d 64 000 ~ 100 Get-Tint 8 g e 65 000 ~ 100 Get-PIP 8 mode Get-PIP input 8 g t 74 000: OFF 001: PIP (POP) 002: PBP g u 75 000 ~ See Set-input select Get-Tiling 8 Mode Get-Tiling 8 Compensa- tion g v 76 000: OFF (for Video wall) 001: ON g w 77 000: OFF (for Video wall) 001: ON Bezel width compen- sation Get-Tiling H 8 by V monitors Get-Tiling 8 position Get-Date: 8 Year Get-Date: 8 Month Get-Date: 8 Day Get-Time: 8 Hour Get-Time: 8 Min Get-Time: 8 Sec Get-RS232 8 version g x 78 01x~09x: H moni- (for Video wall) tors 1. 2nd digital for H 0x1~0x9: V moni- monitors tors 2. 3rd digital for V monitors g y 79 000: OFF (for Video wall) 001~025 Copy the screen of Position# to identified display g 2 32 Y00~Y00 Last 2 digits (20)17~(20)99 g 2 32 M00~M00 2 digits g 2 32 D00~M00 2 digits g 3 33 H00~H00 24-hr format. 2 digits g 3 33 M00~M00 2 digits g 3 33 S00~S00 2 digits g 6 36 001~ Version 0.0.1~9.9.9 NOTE: 1. Get Date example Assumed the current date of display#01 as below Date: 2017-3/15 Send: 0x 38 30 31 67 32 59 30 30 0D (Get Date:Year) Reply: 0x 38 30 31 72 32 59 31 37 0D ("Y17") 91