Tripp Lite SR45UBSD Owner's Manual for Smart Rack Enclosures 932723 - Page 2
Important Safety Instructions, Overview
View all Tripp Lite SR45UBSD manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
Important Safety Instructions SAVE THESE INSTRUCTIONS All sections of this manual contain instructions and warnings that should be followed during the installation and use of the SmartRack Enclosures described in this manual. Read all instructions and warnings thoroughly before attempting to move, install or use the SmartRack Enclosures described in this manual. Failure to comply will create a risk of personal injury and property damage and may invalidate the warranty. • Keep the enclosure in a controlled indoor environment, away from moisture, temperature extremes, flammable liquids and gasses, conductive contaminants, dust and direct sunlight. • Leave adequate space at the front and rear of the enclosure for proper ventilation. Do not block, cover or insert objects into the external ventilation openings of the enclosure. • The enclosure is extremely heavy. Use caution when handling the enclosure. Do not attempt to unpack, move or install it unassisted. Use a mechanical device such as a forklift or pallet jack to move the enclosure in the shipping container. • Do not place any object on the enclosure, especially containers of liquid, and do not attempt to stack the enclosures. • Inspect the shipping container and the enclosure for shipping damage. Do not use the enclosure if it is damaged. • Leave the enclosure in the shipping container until it has been moved as close to the final installation location as possible. The casters are designed for minor position adjustments within the final installation area only. The casters are not designed for moving the enclosure over longer distances. • The casters are not designed to provide long-term support for the enclosure after final installation. Use the levelers to provide long-term support. • Install the enclosure in a structurally sound area with a level floor that is able to bear the weight of the enclosure, all equipment that will be installed in the enclosure and any other enclosures and/or equipment that will be installed nearby. • Do not push the enclosure from the side panels to move it. Pushing from the side panels will cause a tipping hazard. • When rolling the enclosure on its casters, always push it from behind, never pull it toward you. • A rolling enclosure can cause personal injury and property damage if not properly supervised. If rolling the enclosure down a ramp is required, use extreme caution. Do not attempt to use ramps that have a slope steeper than 1:12. • Use caution when cutting packing materials. The enclosure could be scratched, causing damage not covered by the warranty. • Save all packing materials for later use. Repacking and shipping the enclosure without the original packing materials may cause product damage that will void the warranty. • Do not re-ship the enclosure with additional equipment unless the enclosure was shipped with a special shock pallet ("SP1" models only). The combined weight of the enclosure and installed equipment must not exceed the load capacity of the pallet. Tripp Lite is not responsible for any damage that occurs during re-shipment. • Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended. Do not use this equipment in the presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide. Overview SmartRack Enclosures accommodate all standard 19-inch rackmount equipment, regardless of vendor, and ship fully assembled for quick and easy deployment. They feature adaptable, heavy-duty cabinets in 24U, 42U, 45U and 48U heights, with or without side panels. Several models are available with an integrated shock pallet that allows resellers, integrators and enterprise customers to pre-configure equipment and re-ship the enclosures to the final installation site. SmartRack Enclosures have variable mounting depths, ideal for servers. Integrated baying hardware enables cost-effective, orderly and efficient expansion. The cabinets include quick-release doors and side panels for convenient maintenance and split rear doors for improved access and reduced clearance requirements. Front access doors are reversible for installation flexibility. Front and rear doors and side panels are lockable. Model # SR24UB SR24UBEXP SR24UBEXPSP1 SR24UBSP1 SR42UB SR42UBCL SR42UBDP SR42UBDPWD SR42UBEXP SR42UBEXPND SR42UBEXPSP1 SR42UBSP1 SR42UBWD SR42UBWDCL SR45UB SR48UB SR48UBCL SR48UBDP SR48UBDPWD SR48UBEXP SR48UBEXPSP1 SR48UBSP1 Available SmartRack Enclosures Rack Height 24U 24U 24U 24U 42U 42U 42U 42U 42U 42U 42U 42U 42U 42U 45U 48U 48U 48U 48U 48U 48U 48U Side Panels Yes No No Yes Yes Yes Yes Yes No No No Yes Yes Yes Yes Yes Yes Yes Yes No No Yes See the Specifications section for more information. Shock Pallet No No Yes Yes No No No No No No Yes Yes No No No No No No No No Yes Yes 2 201112001_L 93-2723.indd 2 12/14/2011 11:27:13 AM