TRENDnet TE-210T Manual - Page 42

Link Up or Link Down

Page 42 highlights

authentication purpose. The print server supports up to two community names. The default community name is public (case-sensitive), with Read Only access right in default. When an unusual condition or activity occurs, the SNMP agent alerts the SNMP manager through SNMP traps. Following list summaries SNMP trap messages that the print server will send out. Activities/SNMP Trap Messages Description Link Up or Link Down When the network interface on the print server fails, a link down trap message is generated; if the network interface comes back to life, a link up trap message is sent. Cold Start or Warm Start When the print server restarts, the cold start or warm start trap message is generated. Authentication Failure When the print server received a SNMP request with a community name that does not match the community name the print server is configured with (stored in the print server's memory), an authentication failure trap message is generated. In the print server's SNMP implementation, the following MIB objects are available for updating. MIB Object Names system.sysContact Description Indicates the network administrator's name. system.sysName Indicates the print server's name for identification. system.sysLocation Indicates the location of the print server. snmp.snmpEnableAuthenTraps Enables or disables the function of sending SNMP Authentication Failure trap message to the network administrator, if the community name within a SNMP request is not correct. Users can set up print server's SNMP functions by using their browsers. 1.Click Setup, it then appears the sub-menu. 2.Click SNMP, it then as shown in the following picture. 40

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74

authentication purpose. The print server supports up to two community names. The default
community name is
public
(case-sensitive), with
Read Only
access right in default.
When an unusual condition or activity occurs, the SNMP agent alerts the SNMP
manager through
SNMP traps
. Following list summaries SNMP trap messages that the print
server will send out.
Activities/SNMP Trap Messages
Description
Link Up or Link Down
When the network interface on the print server fails, a link down
trap message is generated; if the network interface comes back
to life, a link up trap message is sent.
Cold Start or Warm Start
When the print server restarts, the cold start or warm start trap
message is generated.
Authentication Failure
When the print server received a SNMP request with a
community name that does not match the community name the
print server is configured with
(stored in the print server's
memory), an
authentication failure trap message is generated.
In the print server's SNMP implementation, the following MIB objects are available for
updating.
MIB Object Names
Description
system.sysContact
Indicates the network administrator's name.
system.sysName
Indicates the print server's name for identification.
system.sysLocation
Indicates the location of the print server.
snmp.snmpEnableAuthenTraps
Enables or disables the function of sending SNMP Authentication
Failure trap message to the network administrator, if the
community name within a SNMP request is not correct.
Users can set up print server’s SNMP functions by using their browsers.
1.Click
Setup
, it then appears the sub-menu.
2.Click
SNMP
, it then as shown in the following picture.
40