Sub-Zero 427R Wine Storage Installation Instructions - Page 11

Level the Unit, Home Alarm Connections, Models 424G and 424FSG Installation - stripes

Page 11 highlights

Models 424G and 424FSG Installation 11 subzero.com Level the Unit Using an adjustable wrench or pliers, turn each of the four leveling legs clockwise to raise the unit and counterclockwise to lower the unit. Refer to the illustration below for location of the leveling legs. For model 424G, the countertop bracket should be used to make a solid installation. Refer to the illustration on page 8. If this is not possible, wedge shims along the sides and top. To reduce the possibility of the unit tipping forward, the front leveling legs must be in contact with the floor. Home Alarm Connections Before the kickplate is installed, all necessary wiring connections in the compressor compartment should be completed. If a home alarm system is to be installed on the wine storage unit, the connections should be made using the logic supplied with the alarm specifications. Refer to the illustration for the appliance lead locations, and refer to the following for color codes: • Normally open contacts - white with red stripe wire • Normally closed contacts - white with blue stripe wire • Common - gray with white stripe wire Use the 1/4" spade terminals or wire nuts provided to make the proper wiring connections. IMPORTANT NOTE: If you are not responsible for alarm system connection, this information should be supplied to the home security system contractor. LEVELING LEGS Leveling legs. HOME ALARM CONNECTIONS Home alarm connections. The alarm circuit in the unit is intended as a lowvoltage, low-current device only. It should not be used to switch line power. Any unused terminals should be completely insulated and all wires should be secured away from conductive or moving components.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

Level the Unit
Using an adjustable wrench or pliers, turn each of the four
leveling legs clockwise to raise the unit and counterclock-
wise to lower the unit. Refer to the illustration below for
location of the leveling legs.
For model 424G, the countertop bracket should be used
to make a solid installation. Refer to the illustration on
page 8. If this is not possible, wedge shims along the
sides and top.
Home Alarm Connections
Before the kickplate is installed, all necessary wiring
connections in the compressor compartment should be
completed.
If a home alarm system is to be installed on the wine
storage unit, the connections should be made using the
logic supplied with the alarm specifications. Refer to the
illustration for the appliance lead locations, and refer to
the following for color codes:
Normally open contacts – white with red stripe wire
Normally closed contacts – white with blue stripe wire
Common – gray with white stripe wire
Use the
1
/
4
" spade terminals or wire nuts provided to
make the proper wiring connections.
IMPORTANT NOTE:
If you are not responsible for alarm
system connection, this information should be supplied to
the home security system contractor.
Models 424G and 424FSG Installation
11
subzero.com
The alarm circuit in the unit is intended as a low-
voltage, low-current device only. It should not be used
to switch line power.
Any unused terminals should be completely insulated
and all wires should be secured away from conductive
or moving components.
To reduce the possibility of the unit tipping forward, the
front leveling legs must be in contact with the floor.
LEVELING LEGS
Leveling legs.
Home alarm connections.
HOME ALARM