Sharp PN-455P PN-455 Operation Manual - Page 47
RS-232C command table
View all Sharp PN-455P manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 47 highlights
ENGLISH RS-232C command table Command: Command field (See page 40.) Direction: W When the "Parameter" is set in the parameter field (see page 40), the command functions as described under "Control/Response Contents". R The returned value indicated under "Reply" can be obtained by setting or "???+" (repeater control) in the parameter field (see page 40). Parameter: Parameter field (See page 40.) Reply: Response (Returned value) * A circle indicates commands which can be used in power standby mode. Power control/Input selection, etc. Control item Power Setting Input Selection Command Direction Parameter Reply 0 W 1 POWR 0 R 1 2 0 1 W 2 3 INPS 4 1 2 R 3 4 *can be used in standby mode Control/Response contents * Switches to standby. Returns from standby. Standby mode Yes Normal mode Waiting mode Toggle change INPUT1 : DVI INPUT2 : RGB INPUT3 : Component INPUT4 : S-Video/Video Yes INPUT1 : DVI INPUT2 : RGB INPUT3 : Component INPUT4 : S-Video/Video 47 E