Sharp AF-S50CX AF-R50CX , AF-R60CX , AF-R70CX Operation Manual - Page 6
Installation
View all Sharp AF-S50CX manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
INSTALLATION INSTRUCTIONS INSTALLATION WARNING: Make sure the unit is turned off and unplugged before working. 1 Cut the window sash foam seal (adhesive type) to the proper length and attach it to the underside of the window sash. Jamb Sash Window sash foam seal (adhesive type) Sill 2 Insert the right closure assembly and the left closure assembly into the top angle and the bottom channels. Secure the right and left closure to the cabinet with six of the provided screws. (L= 13/32", 10mm) Closure assembly 3 Open the window sash and place the air conditioner on the sill. Balance the unit on the sill and close the window sash securely behind the top angle. WARNING: At this step, make sure the unit is inclined approximately 1 cm (3/8") to the back. If the unit is not properly inclined, the water collected in the bottom tray during operation will not drain properly and may flow into the room where the air conditioner is installed. unit sill incline backwards approximately 1cm (3/8") 4 Insert the bottom gasket into the space between the window sill and the bottom of the unit to seal outside air. If there is space between the bottom channel and the sill, fill the gap with a thin board or other hard filler. 6 Bottom gasket