Sennheiser SKP 100 G3 Instructions for Use

Sennheiser SKP 100 G3 Manual

Sennheiser SKP 100 G3 manual content summary:

  • Sennheiser SKP 100 G3 | Instructions for Use - Page 1
    SKP 100 Instruction manual
  • Sennheiser SKP 100 G3 | Instructions for Use - Page 2
    operation 17 Cleaning the plug-on transmitter 18 Recommendations and tips 18 If a problem occurs 19 Accessories ...20 Specifications ...21 Manufacturer Declarations 22 Index ...23 Supplementary information can be found on the SKP 100 G3 product page on our website at www.sennheiser.com. 1
  • Sennheiser SKP 100 G3 | Instructions for Use - Page 3
    parts specified by Sennheiser or those having the same characteristics as the original part. Unauthorized substitutions may result in fire, electric shock, or other hazards. Intended use Intended use of the ew 100 G3 series products includes: • having read these instructions, especially the chapter
  • Sennheiser SKP 100 G3 | Instructions for Use - Page 4
    SKP 100 G3 plug-on transmitter This plug-on transmitter is part of the evolution wireless series generation 3 (ew G3). With this series, Sennheiser offers high-quality state-of-the-art RF transmission systems with a high level of operational reliability and ease of use. Transmitters and receivers
  • Sennheiser SKP 100 G3 | Instructions for Use - Page 5
    frequency information sheet can be downloaded from the SKP 100 G3 product page on our website at www.sennheiser.com. The frequency bank "U" allows you to contains the following items: 1 SKP 100 G3 plug-on transmitter 2 AA size batteries, 1.5 V 1 instruction manual 1 frequency information sheet 1 RF
  • Sennheiser SKP 100 G3 | Instructions for Use - Page 6
    Product overview Product overview Overview of the SKP 100 G3 plug-on transmitter ³ · » ¿ ´ ² ¶ º ³ Microphone input, XLR-3 socket (female, unbalanced) · Mechanical locking ew100 G3 AF P MUTE ቧ ቨ ቩ Display Meaning ቢ Audio level "AF" ባ Frequency Modulation of the plug-on transmitter with
  • Sennheiser SKP 100 G3 | Instructions for Use - Page 7
    accupack. Standard batteries (primary cells) or individual rechargeable battery cells cannot be charged. Plugging the plug-on transmitter onto a microphone ̈ Plug the microphone's XLR-3M socket onto the transmitter's XLR-3F socket ³. ³ · ̈ Tighten the locking ring · in the direction of the arrow
  • Sennheiser SKP 100 G3 | Instructions for Use - Page 8
    receiver on (see the instruction manual of the receiver). 2. Switch the plug-on transmitter on (see next section). The transmission link is established and the diversity receiver plug-on transmitter does not transmit an RF signal. The transmission icon ብ is not displayed. 533.875MHz ብ ew100 G3
  • Sennheiser SKP 100 G3 | Instructions for Use - Page 9
    you have to temporarily deactivate it i0n order to be able to operate the plug-on transmitter: ̈ Press the ON/OFF button. ON/OFF "Locked" appears on the ቦ flashes prior to the lock mode being activated again. 533.875MHz ew100 G3 ቦ AF P MUTE Muting the audio signal or deactivating the RF
  • Sennheiser SKP 100 G3 | Instructions for Use - Page 10
    in the table. The current state of the muting function or the RF signal is displayed on the display panel of the plug-on transmitter: 533.875MHz ብ ew100 G3 AF P MUTE ቨ State Audio signal is muted Audio signal is activated (muting is canceled) RF signal is deactivated RF signal is activated
  • Sennheiser SKP 100 G3 | Instructions for Use - Page 11
    Using the operating menu Using the operating menu A special feature of the Sennheiser ew G3 series is the consistent, intuitive menu structure of transmitters and receivers. As a result, adjustments to the settings can be made quickly - even in stressful situations, for example on stage or during a
  • Sennheiser SKP 100 G3 | Instructions for Use - Page 12
    Using the operating menu Display Function of the menu item LCD Contrast Adjusts the contrast of the display panel Reset Resets the settings made in the operating menu Software Revision Displays the current software revision Exit Exits the extended menu "Advanced Menu" and returns to the
  • Sennheiser SKP 100 G3 | Instructions for Use - Page 13
    Using the operating menu Exiting a menu item ̈ Change to the "Exit" menu item. Menu Exit SET ̈ Confirm your selection. You return to the next higher menu level or you exit the operating menu and return to the current standard display. To directly return to the current standard display: ̈ Press the
  • Sennheiser SKP 100 G3 | Instructions for Use - Page 14
    receiver and to transfer these settings to the plugon transmitter. For more information, refer to the instruction manual of the receiver if the plug-on transmitter is microphones, adjust a high input sensitivity when using dynamic microphones. Selecting the frequency bank and the channel manually
  • Sennheiser SKP 100 G3 | Instructions for Use - Page 15
    ; store the setting "Stored" SET Via the "Name" menu item, you can enter a freely selectable name (e.g. the name of the performer) for the plug-on transmitter. The name can be displayed on the "Frequency/Name" and "Name/ Channel" standard displays (see page 9). The name can consist of up to
  • Sennheiser SKP 100 G3 | Instructions for Use - Page 16
    frequencies and the frequency bank "U" - "Tune" When you have selected one of the system banks and then select the "Tune" menu, the plug-on transmitter automatically switches to channel 1 of the frequency bank "U". In this case, "U.1" briefly appears on the display panel. Upon delivery, the channels
  • Sennheiser SKP 100 G3 | Instructions for Use - Page 17
    ew 100 G1 series (generation 1) do not support the pilot tone function. Therefore, please observe the following when combining a transmitter or receiver of the ew 100 G3 series (generation 3) with devices from an earlier evolution wireless generation: Transmitter Receiver Make sure to ... w G3
  • Sennheiser SKP 100 G3 | Instructions for Use - Page 18
    used in multi-channel systems. For information on automatic synchronization of plug-on transmitters with receivers (multi-channel operation), refer to the instruction manual of your receiver. For more information on multi-channel operation, visit the SKP 100 G3 product page at www.sennheiser.com. 17
  • Sennheiser SKP 100 G3 | Instructions for Use - Page 19
    line of sight" between plug-on transmitter and receiving antennas. • To avoid overloading the receiver, observe a minimum distance of 5 m between plug-on transmitter and receiving antennas. • The plug-on transmitter uses the microphone body as an antenna - therefore microphones with a metal casing
  • Sennheiser SKP 100 G3 | Instructions for Use - Page 20
    page 13). If a problem occurs that is not listed in the above table or if the problem cannot be solved with the proposed solutions, please contact your local Sennheiser partner for assistance. To find a Sennheiser partner in your country, search at www.sennheiser.com under "Service & Support". 19
  • Sennheiser SKP 100 G3 | Instructions for Use - Page 21
    Accessories Accessories The following SKP 100 G3 accessories are available from your specialist dealer: Cat. No. Accessory 009950 BA 2015 accupack 009828 L 2015 charger 005232 POP 1 pouch (with belt clip) 20
  • Sennheiser SKP 100 G3 | Instructions for Use - Page 22
    ) THD Max. input voltage Input impedance Adjustment range of input sensitivity Sennheiser HDX 80-18,000 Hz ≥ 110 dBA ≤0.9 % 3.3 Vrms 60 consumption • at nominal voltage typ. 180 mA • with switched-off plug-on ≤25 µA transmitter Operating time typ. 8 hrs Dimensions approx. 105 mm x 43 mm
  • Sennheiser SKP 100 G3 | Instructions for Use - Page 23
    sennheiser.com or contact your Sennheiser partner. In compliance with the following requirements • RoHS Directive (2002/95/EC) • WEEE Directive (2002/96/EC) Please dispose of the plug-on transmitter must accept any interference received, including interference that with the instructions, may cause
  • Sennheiser SKP 100 G3 | Instructions for Use - Page 24
    a frequency 15 overview 3 selecting (Frequency Preset) 13 setting (Tune) 15 charging accupack 6 battery status display 5 cleaning (plug-on transmitter) 18 connecting (microphones) 6 D deactivating temporarily (lock mode) 8 displays adjusting the contrast of the display panel (LCD Contrast) 16 charge
  • Sennheiser SKP 100 G3 | Instructions for Use - Page 25
    Index microphones connecting 6 overview 3 suitable ~ 3 Mute (muting the audio signal) 8 Mute Mode ( (plug-on transmitter) 7 synchronizing (plug-on transmitter/receiver) 17 T transmission frequency selecting (Frequency Preset) 13 setting (Tune) 15 transmission power, optimizing 18 troubleshooting 19
  • Sennheiser SKP 100 G3 | Instructions for Use - Page 26
    Sennheiser electronic GmbH & Co. KG Am Labor 1, 30900 Wedemark, Germany www.sennheiser.com Printed in Germany Publ. 01/09 529675/A01 Instrucciones de uso