Sanyo PLC-XU300A RS232 Expand - Page 63
CR_FILREPL Command, 11.26 CR_FILTIMER Command
![]() |
UPC - 086483076336
View all Sanyo PLC-XU300A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 63 highlights
PLC-XU300/350 Expand Serial Command Functional Specifications 9.11.25 CR_FILREPL Command Command "CR_FILREPL"[CR] Details Get the information of Filter replacement time Acceptable "000_%1"[CR] Response %1 "1Y Over filter replacement time "1N Within filter replacement time Unacceptable "Error Code"[CR] 9.11.26 CR_FILTIMER Command Command "CR_FILTIMER" [CR] Details Get setting time which filter warning OSD is displayed Acceptable "000_%1"[CR] "100 100 hours Response %1 "200 200 hours "300 300 hours "OFF No OSD display Unacceptable "Error Code"[CR] 62 / 66
![](/manual_guide/products/sanyo-plcxu350a-rs232-expand-32e7827/63.png)
PLC-XU300/350 Expand Serial Command Functional Specifications
62 / 66
9.11.25 CR_FILREPL Command
Command
“CR_FILREPL”[CR]
Details
Get the information of Filter replacement time
Response
Acceptable
“000_%1”[CR]
%1
“1Y” ------------------- Over filter replacement time
“1N” ------------------ Within filter replacement time
Unacceptable
“Error Code”[CR]
9.11.26 CR_FILTIMER Command
Command
“CR_FILTIMER” [CR]
Details
Get setting time which filter warning OSD is displayed
Response
Acceptable
“000_%1”[CR]
%1
“100” ----------------- 100 hours
“200” ----------------- 200 hours
“300” ----------------- 300 hours
“OFF” ---------------- No OSD display
Unacceptable
“Error Code”[CR]