LENS SHIFT UP Command, LENS SHIFT DOWN Command, LENS SHIFT LEFT Command, LENS SHIFT RIGHT Command,
![]() |
View all Sanyo PLC-XM100/L manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications 6.54 LENS SHIFT UP Command Command "C5D" [CR] Detail Move projection area upward. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 6.55 LENS SHIFT DOWN Command Command "C5E" [CR] Detail Move projection area downward. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 6.56 LENS SHIFT LEFT Command Command "C5F" [CR] Detail Move projection area leftward. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 6.57 LENS SHIFT RIGHT Command Command "C60" [CR] Detail Move projection area rightward. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 6.58 AUTO PC ADJ. Command Command "C89" [CR] Detail Execute AUTO PC ADJ. function This command works the same way as "AUTO PC" button of the remote control. Sending this command during Auto PC Adj. process terminates the operation. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 6.59 PRESENTATION TIMER Command Command "C8A" [CR] Detail Start Timer for presentation This command works the same way as "P-TIMER" button of the remote control. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 21/28