Samsung NZ36M9880UB Installation Guide - Page 5
Product dimensions, IMPORTANT
View all Samsung NZ36M9880UB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
Installation requirements Product dimensions A D B C E Cabinet A Frame Depth B Frame width C Case Depth D Case Width E Conduit Case Height F Case Height 30" (mm) 211/4" (540) 30" (762) 191/2" (494.6) 283/8" (720) 4" (101) 31/8" (80.5) F 36" (mm) 211/4" (540) 36" (914) 19" (481.6) 333/4" (856.6) 4" (101) 31/8" (80.5) IMPORTANT: If installing a range hood or microwave hood combination above the cooktop, follow the range hood or microwave hood combination installation instructions for dimensions and clearance above the cooktop surface. Rear Wall C B D Cooktop Countertop E A G F E Minimum distance to combustible side wall above Junction box countertop (both sides) NZ30******* NZ36******* A 281/2" - 2811/16" (724 mm - 728 mm) 337/8" - 34" (860 mm - 864 mm) B 199/16" - 195/8" (497.4 mm - 499.4 mm) 191/8" - 193/16" (485.6 mm - 487.6 mm) C Min 11/8" (28 mm). Between cutout and the wall behind the cooktop D Min 11/2" (38 mm). From front edge of cutout and front edge of countertop E Min 1" (26 mm). Distance nearest left and right side combustible surface above cooktop. F Junction box or outlet 10" (254 mm) maximum from right-hand side of cabinet G Junction box or outlet 15" (381 mm) minimum from bottom of countertop CHEF-INDU_NZ30M9880_NZ36M9880_DG68-00827B-01_EN+MES+CFR.indb 5 English 5 5/25/2018 7:07:52 PM