Pyle PTHDL160 User Guide - Page 1

Pyle PTHDL160 Manual

Page 1 highlights

PTHDL160 Temperature and humidity data logger Introduction: 1. Measure the temperature and humidity online or offline and record them. 2. USB connect to the corresponding software on computer. 3. After connection,read the digits on the computer or download the data. 4. Selectable measure intervals: (1-24)second,minute,hour. 5. Selectable measuring data number 6. Record 21000 temperature and humidity counts simultaneously. 7. LED lights indication. 8. Alarm function of temperature and humidity or set alarm value. 9. Long battery life. Specifications and parameters Temperature measurement range Temperature measurement accuracy Temperature display resolution Humidity measurement range Humidity measurement accuracy Humidity display resolution Using temperature Storage temperature Size Weight Battery -40℃~105℃(-40 ℉~221 ℉) ±1℃(±2 ℉) 0.1℃(0.1℉) 0% RH~100%RH ±3% RH 0.1% RH -40℃~105℃(-40 ℉~221 ℉) -40℃~125℃(-40℉~257℉) 106×24×24mm 25g( no battery) 3.6V The second step After you installed the software, please insert the instrument to the USB interface, next operations please see the diagram Description: 1. Lid 2. USB interface 3. Switch 9 1 4. Battery cover 5. Sensor 2 6. Card clasp, (press it, open the battery cover) 3 7. Alarm lamp (red/yellow) 8 7 8. Record lamp (green) 9. Product tray 4 6 5 The assembly of battery: The methods of battery installment are as follow: When working whether the data logger connect to USB or not,power needed. 1.Press the card clasp, pull out the battery cover. 2.Take out the battery cover. 3.Put in the battery. (the positive pole face to the USB interface) 4. Install the battery cover. The LED light: 1.Green light:working. If flashing, it is working. 2.Red and yellow lights: alarming. If flashing, the measuring data over range the alarm counts. About the flashing regulations of green/yellow/red lamp, refer to the chart below: Usage scenarios Green lamp Installing battery Start measuring flash 3times quick flash 2t USB communication quick flash 1t Recording data slow flash 2t interval time quick flash 1t Low temperature alarm High temperature alarm Low humidity alarm High humidity alarm Red lamp flash 3t flash 1t quick flash 2t Yellow lamp flash 3t slow flash 1t quick flash 2t Usage and maintenance: Installing the battery, connect USB with computer, after setting the digits by using the software, the product can be used. In the process of using, keep entilation clean. About the set of products, please refer to: Help document of communication software. Press the " NEXT" button all the time can be finished the installment. 4 5 We can read the correct datas according to the arrow indicate method. 6

  • 1

Temperature and humidity data logger
Introduction:
1. Measure the temperature and humidity online or offline and record them.
2. USB connect to the corresponding software on computer.
3. After connection,read the digits on the computer or download the data.
4. Selectable measure intervals: (1-24)second,minute,hour.
5. Selectable measuring data number
6. Record 21000 temperature and humidity counts simultaneously.
7. LED lights indication.
8. Alarm function of temperature and humidity or set alarm value.
9. Long battery life.
Specifications and parameters
Temperature measurement range
Temperature measurement accuracy
Temperature display resolution
Humidity measurement range
Humidity measurement accuracy
Humidity display resolution
Using temperature
Storage temperature
Size
Weight
Battery
1
2
3
4
5
6
7
8
9
Description
:
1. Lid
2. USB interface
3. Switch
4. Battery cover
5. Sensor
6. Card clasp, (press it, open the battery cover)
7. Alarm lamp (red/yellow)
8. Record lamp (green)
9. Product tray
The assembly of battery
:
The methods of battery installment are as follow:
When working whether the data logger connect to USB or not,power needed.
1.Press the card clasp, pull out the battery cover.
2.Take out the battery cover.
3.Put in the battery. (the positive pole face to the USB interface)
4. Install the battery cover.
The LED light
:
1.Green light:working. If flashing, it is working.
2.Red and yellow lights: alarming. If flashing, the measuring data over range
the alarm counts.
About the flashing regulations of green/yellow/red lamp, refer to the chart
below:
Usage scenarios
Green lamp
Red lamp
Yellow lamp
Installing battery
flash 3times
flash 3t
flash 3t
Start measuring
quick flash 2t
USB communication
quick flash 1t
Recording data
slow flash 2t
interval time
quick flash 1t
Low temperature alarm
flash 1t
High temperature alarm
quick flash 2t
slow flash 1t
Low humidity alarm
High humidity alarm
quick flash 2t
Usage and maintenance
:
Installing the battery, connect USB with computer, after setting the digits by
using the software, the product can be used. In the process of using, keep
entilation clean.
About the set of products, please refer to:
Help document of communication
software.
-40
~105
℃(
-40
~221
℉)
±1
℃(
±2
℉)
0.1
℃(
0.1
℉)
0% RH~100%RH
±3% RH
0.1% RH
-40
~105
℃(
-40
~221
℉)
-40
~125
℃(
-40
~257
℉)
106×24×24mm
25g( no battery)
3.6V
PTHDL160
The second step
4
Press the " NEXT" button all the time can be finished the installment.
After you installed the software,
please insert the instrument to the USB interface,
next operations please see the diagram
5
6
We can read the correct datas according to the
arrow indicate method.