Panasonic WVSP306 WVSP302 User Guide - Page 63

Con the settings relating to the alarm output terminal [Alarm], Alarm output trigger], Default

Page 63 highlights

Configure the settings relating to the alarm output terminal [Alarm] Click the [Alarm] tab on the "Alarm" page. (☞ Pages 22 and 23: How to display/operate the setup menu) The settings relating to the alarm output terminal can be configured in this section. [Pulse width] When "Pulse" is selected for "Alarm output type", select an alarm output terminal duration from the following. Available range: 1 - 120sec Default: 1sec ■ Alarm output terminal setup [Alarm output trigger] Select "On" or "Off" to determine whether or not to output the alarm signals to the alarm output terminal when an alarm is detected. Default: Off [Alarm output type] Select "Latch" or "Pulse" for the alarm output terminal at an alarm occurrence. Latch: When an alarm is detected, the alarm output terminal will be in the state selected for "Trigger output" until the alarm occurrence indication button is clicked. Pulse: When an alarm is detected, the alarm output terminal will be in the state to the "Trigger output" setting for the period set for "Pulse width". Default: Latch [Trigger output] Select "Open" or "Close" to determine whether to open or close the alarm output terminal when outputting the alarm signals. Open: The alarm output terminal will open when out- putting the alarm signals. (Normally close) Close: The alarm output terminal will close when out- putting the alarm signals. (Normally open) Default: Close Note: • When "Open" is selected, the alarm signal will be output for around 20 seconds when the power of the camera is turned on. 63

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102

63
Alarm output terminal setup
[Alarm output trigger]
Select "On" or "Off" to determine whether or not to out
-
put the alarm signals to the alarm output terminal when
an alarm is detected.
Default:
Off
[Alarm output type]
Select "Latch" or "Pulse" for the alarm output terminal
at an alarm occurrence.
Latch:
When an alarm is detected, the alarm output
terminal will be in the state selected for "Trigger out-
put" until the alarm occurrence indication button is
clicked.
Pulse:
When an alarm is detected, the alarm output ter-
minal will be in the state to the "Trigger output"
set-
ting for the period set for "Pulse width".
Default:
Latch
[Trigger output]
Select "Open" or "Close" to determine whether to open
or close the alarm output terminal when outputting the
alarm signals.
Open:
The alarm output terminal will open when out-
putting the alarm signals. (Normally close)
Close:
The alarm output terminal will close when out-
putting the alarm signals. (Normally open)
Default:
Close
Note:
• When "Open" is selected, the alarm signal will be
output for around 20 seconds when the power of
the camera is turned on.
[Pulse width]
When "Pulse" is selected for "Alarm output type",
select an alarm output terminal duration from the fol-
lowing.
Available range:
1 - 120sec
Default:
1sec
Configure the settings relating to the alarm output terminal [Alarm]
Click the [Alarm] tab on the "Alarm" page. (
Pages 22 and 23: How to display/operate the setup menu)
The settings relating to the alarm output terminal can be configured in this section.