When "ON" is selected, the zoom factor and the panning/tilting settings can be configured. Follow the procedure below. "SYSTEM SETUP" screen **SYSTEM SETUP** SYNC INT PRIVACY ZONE OFF STABILIZER OFF EL-ZOOM ON UPSIDE-DOWN OFF LDC I...... 0 - + EL-zoom setting screen **EL-ZOOM** ZOOM PAN/TILT PUSH SET PUSH SET Zoom setting screen **EL-ZOOM** ZOOM PAN/TILT PUSH SET PUSH SET U ZOOM D Pan/tilt setting screen **EL-ZOOM** ZOOM PAN/TILT PUSH SET PUSH SET U ZOOM D L PAN R RET TOP END RET TOP END RET TOP END Step 1 Move the cursor to "EL-ZOOM", select "ON" and press the [SET ] button. → The "EL-ZOOM" setting screen will be displayed. RET TOP END Step 2 Move the cursor to "PUSH SET" of "ZOOM" and press the [SET ] button. → The zoom setting screen appears. Step 3 Adjust the angular field of view by changing the electronic zoom factor (up to 2x) using the [up] or [down] button, and press the [SET] button. Note: • When the zoom factor is incremented, resolution will be deteriorated. Step 4 Move the cursor to "PUSH SET" of "PAN/TILT" and press the [SET ] button. → The pan/tilt setting screen appears. Step 5 Use the [up], [down], [right], and [left ] buttons to determine the position of the area to be set and press the [SET] button. The position can be changed in the range of zoom factor set in the "ZOOM" setting screen. D Upside-down setting [UPSIDE-DOWN] ON: The video image can be reversed upside down. OFF (default): The video image cannot be reversed upside down. E Lens distortion correction [LDC] The image may be distorted depending on the lens used and the zoom factor. By adjusting the lens distortion correction setting, the distorted image can be converted to match the square monitor and achieve effects desired by the user. Note: • Depending on the lens used, complete correction may not be achieved. 22

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

22
When "ON" is selected, the zoom factor and the panning/tilting settings can be configured.
Follow the procedure below.
**
EL-ZOOM
**
PUSH SET
PUSH SET
**
EL-ZOOM
**
PUSH SET
PUSH SET
**
EL-ZOOM
**
PUSH SET
PUSH SET
ZOOM
PAN/TILT
ZOOM
PAN/TILT
ZOOM
PAN/TILT
U ZOOM D
U ZOOM D
L PAN R
“SYSTEM SETUP” screen
EL-zoom setting screen
Pan/tilt setting screen
Zoom setting screen
RET TOP END
RET TOP END
RET TOP END
OFF
**SYSTEM SETUP**
SYNC
INT
PRIVACY ZONE
STABILIZER
OFF
EL-ZOOM
ON
UPSIDE-DOWN
OFF
-
+
LDC
I
......
0
RET TOP END
Step 1
Move the cursor to "EL-ZOOM", select "ON" and press the [SET] button.
The "EL-ZOOM" setting screen will be displayed.
Step 2
Move the cursor to "PUSH SET" of "ZOOM" and press the [SET] button.
The zoom setting screen appears.
Step 3
Adjust the angular field of view by changing the electronic zoom factor (up to 2x) using the [UP]
or [DOWN] button, and press the [SET] button.
Note:
• When the zoom f
actor is incremented, resolution will be deteriorated.
Step 4
Move the cursor to "PUSH SET" of "PAN/TILT" and press the [SET] button.
The pan/tilt setting screen appears.
Step 5
Use the [UP], [DOWN], [RIGHT], and [LEFT] buttons to determine the position of the area to be
set and press the [SET] button.
The position can be changed in the range of zoom factor set in the "ZOOM" setting screen.
D
Upside-down setting [UPSIDE-DOWN]
ON:
The video image can be reversed upside down.
OFF (default):
The video image cannot be reversed upside down.
E
Lens distortion correction [LDC]
The image may be distorted depending on the lens used and the zoom factor. By adjusting the
lens distortion correction setting, the distorted image can be converted to match the square
monitor and achieve effects desired by the user.
Note: