Panasonic AW-RP150GJ AW-RP150 Interface Specifications - Page 8

Command sequence In case of AW-RP120, AW-RP150 and AW-RP60

Page 8 highlights

Remote Camera Controller Interface Specifications As per the command format described on the previous page, the command sequence which is followed when communication is performed is shown below. For details of the sequence followed when an error has occurred in response to a command, refer to "7. Error return". Command sequence (In case of AW-RP120, AW-RP150 and AW-RP60) 【Sequence】 "PC" means control terminal in the sequence below. Example: Camera switching to CAM1 Camera IP Address = 192.168.0.10 Command = XCN:01:1 The controller switching is controlled from the PC, and [HTTP/1.1 200 OK] is returned as the response from controllwe. See the command sequence below. PC Controller CONNECT 1 http://192.168.0.10/cgi-bin/aw_cam?cmd=XCN:01:1&res=1 2 HTTP/1.1 200 OK CLOSE Fig.4.1-1 Command sequence of controller When controller receives a command from the PC, the controller may sometime control the camera as well. This involves the preset memory and tracing memory. Preset play control is exercised from the PC, and [HTTP/1.1 200 OK] is returned as the response. Given below is the command sequence. PC Controller Camera cgi-bin/aw_cam?cmd=XPM:01:001&res=1 Preset No.1 play request (#R command) HTTP/1.1 200 OK Preset No.1 play response (s command) Preset No.1 play finish notification (q command) response Fig.4.1-2 Command sequence of controller control (Preset memory, etc.) To receive preset playback completion notifications on the PC, connect directly to the camera and receive update notifications. © Panasonic Corporation 2020 All Rights Reserved. - 8 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25

Remote Camera Controller
Interface Specifications
©
Panasonic Corporation 2020 All Rights Reserved.
- 8 -
1
2
As per the command format described on the previous page, the command sequence which is
followed when communication is performed is shown below.
For details of the sequence followed when an error has occurred in response to a command, refer to
“7. Error return”.
Command sequence (In case of AW-RP120, AW-RP150 and AW-RP60)
Sequence
“PC” means control terminal in the sequence below.
Example:
Camera switching to CAM1
Camera IP Address = 192.168.0.10
Command = XCN:01:1
The controller switching is controlled from the PC, and [HTTP/1.1 200 OK] is returned as the
response from controllwe. See the command sequence below.
Fig.4.1-1
Command sequence of controller
When controller receives a command from the PC, the controller may sometime control the camera
as well. This involves the preset memory and tracing memory.
Preset play control is exercised from the PC, and [HTTP/1.1 200 OK] is returned as the response.
Given below is the command sequence.
Fig.4.1-2
Command sequence of controller control (Preset memory, etc.)
To receive preset playback completion notifications on the PC, connect directly to the camera and
receive update notifications.
Preset No.1 play response (s command)
Controller
Camera
PC
cgi-bin/aw_cam?cmd=XPM:01:001&res=1
HTTP/1.1 200 OK
Preset No.1 play request (#R command)
Preset No.1 play finish notification
(q command) response
PC
Controller
HTTP/1.1 200 OK
CLOSE
CONNECT