Table of adjustment setting ranges Menu CINE Gamma ASU Tally Guard G / L Shutter ROM Version PLD Version Format Item Cinema Gamma SW Cinema Gamma SEL Black STR LVL Dynamic LVL Knee Point Knee Slope Filter Setup Mode REF File M-PED Target ASU Execute Tally Guard H Phase-Coarse H Phase-Fine SD-HD Phase CRS SD-HD Phase Fine HD-SD Phase CRS HD-SD Phase Fine SD-HD V Phase SC Coarse SC Fine SC-H Coarse SC-H Fine Shutter SYNCHRO Mode Speed CAM B, U (*4) TG SHD MEM RET VF AUX CAMSYS OPTION Present Format Adjustment setting range NORMAL, ON VIDEO_REC, FILM_REC 0 to 30 200 %, 300 %, 400 %, 500 % +30 to +90 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 REF, Current FULL (standard), EASY (simplified) Factory, User1, User2, User3 0.0 % to 7.5 % (execution items) OFF, ON -60 to +60 (during HD signal genlock) -120 to +120 (during SD signal genlock) -45 to +45 -4 to +4 -99 to +99 -7 to +8 -99 to +99 SD, HD 1 to 8 -255 to +255 1 to 8 -255 to +255 OFF, ON OFF, ON Fixed at SHUTTER When SHUTTER is ON, SYNCHRO is OFF 100/125/250/500/1000/2000 When SHUTTER is ON, SYNCHRO is ON 60.9 Hz to 99.8 Hz When SHUTTER is OFF, SYNCHRO is ON 60.9 Hz to 99.8 Hz When SHUTTER is OFF, SYNCHRO is OFF 100/125/250/500/1000/2000 (Display item) (Display item) (Display item) (Display item) (Display item) (Display item) (Display item) (Display item) (Display item) (Display item) 50 i, 59.94 i, 23.98p, 24p, 25p, 29.98p, 30p Initial value NORMAL VIDEO_REC 30 200 % +30 150 REF FULL Factory 5.0 % - OFF 0 0 0 0 0 0 SD 1 0 1 0 OFF OFF SHUTTER When SHUTTER is ON, SYNCHRO is OFF: 100 When SHUTTER is ON, SYNCHRO is ON: 60.9 When SHUTTER is OFF, SYNCHRO is ON: 60.9 When SHUTTER is OFF, SYNCHRO is OFF: 100 (Current value) (Current value) (Current value) (Current value) (Current value) (Current value) (Current value) (Current value) (Current value) (Current value) 59.94 i *4: This is displayed when the buildup unit is connected. 36

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

36
Menu
Item
Adjustment setting range
Initial value
CINE Gamma
Cinema Gamma SW
NORMAL, ON
NORMAL
Cinema Gamma SEL
VIDEO_REC, FILM_REC
VIDEO_REC
Black STR LVL
0 to 30
30
Dynamic LVL
±00 %, 300 %, 400 %, 500 %
±00 %
Knee Point
+30 to +90
+30
Knee Slope
150, ±00, ±50, 300, 350, 400, 450, 500, 550, 600
150
ASU
Filter
REF, Current
REF
Setup Mode
FULL (standard), EASY (simplified)
FULL
REF File
Factory, User1, User±, User3
Factory
M-PED Target
0.0 % to 7.5 %
5.0 %
ASU Execute
(execution items)
Tally Guard
Tally Guard
OFF, ON
OFF
G / L
H Phase-Coarse
–60 to +60 (during HD signal genlock)
–1±0 to +1±0 (during SD signal genlock)
0
H Phase-Fine
–45 to +45
0
SD-HD Phase CRS
–4 to +4
0
SD-HD Phase Fine
–99 to +99
0
HD-SD Phase CRS
–7 to +8
0
HD-SD Phase Fine
–99 to +99
0
SD-HD V Phase
SD, HD
SD
SC Coarse
1 to 8
1
SC Fine
–±55 to +±55
0
SC-H Coarse
1 to 8
1
SC-H Fine
–±55 to +±55
0
Shutter
Shutter
OFF, ON
OFF
SYNCHRO
OFF, ON
OFF
Mode
Fixed at SHUTTER
SHUTTER
Speed
When SHUTTER is ON, SYNCHRO is OFF
100/1±5/±50/500/1000/±000
When SHUTTER is ON, SYNCHRO is ON
60.9 Hz to 99.8 Hz
When SHUTTER is OFF, SYNCHRO is ON
60.9 Hz to 99.8 Hz
When SHUTTER is OFF, SYNCHRO is OFF
100/1±5/±50/500/1000/±000
When SHUTTER is ON,
SYNCHRO is OFF: 100
When SHUTTER is ON,
SYNCHRO is ON: 60.9
When SHUTTER is OFF,
SYNCHRO is ON: 60.9
When SHUTTER is OFF,
SYNCHRO is OFF: 100
ROM Version
CAM
(Display item)
(Current value)
B, U (*4)
(Display item)
(Current value)
PLD Version
TG
(Display item)
(Current value)
SHD
(Display item)
(Current value)
MEM
(Display item)
(Current value)
RET VF
(Display item)
(Current value)
AUX
(Display item)
(Current value)
CAMSYS
(Display item)
(Current value)
OPTION
(Display item)
(Current value)
Format
Present
(Display item)
(Current value)
Format
50 i, 59.94 i, ±3.98p, ±4p, ±5p, ±9.98p, 30p
59.94 i