Panamax M5300 Owners Manual - Page 13

Technical Specifications, Contacting Panamax - dimensions

Page 13 highlights

TECHNICAL SPECIFICATIONS GENERAL Dimensions 17.25" W x 12" D x 3.5" H Weight 16 lbs. AC CIRCUIT NOISE FILTRATION: Filtered Outlet Banks 55 dB (100 KHz - 1 MHz) High-Current Outlets 50 dB (100 KHz - 1 MHz) SURGE PROTECTION: UL 1449 Surge Suppression Rating 330V Protection Modes L - N, L - G, N - G Initial Clamping Level 200V Peak, 141V Rms Response Time 1ns Joule Rating 1790 Joules Peak Impulse Current 65,000A Catastrophic Surge Circuit YES AC: Line Voltage 120VAC Max Current Rating 15A (1800 Watts) Thermal Fuse YES Over/Under Voltage Protection YES Over-voltage shutoff threshold 132V Under-voltage shutoff threshold 90V Design and specifications subject to change without notice due to product improvement. DC TRIGGER Connection 1/8" mini-plug Voltage and Polarity 12VDC, bi-directional Current Requirement 30mA SATELLITE CIRCUIT Clamping Level 27V Attenuation 1 dB from 950MHz - 2.05GHz

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14

USA & Canada (800) 472-5555
(415) 499-3900
Fax (415) 472-5540
11
TECHNICAL SPECIFICATIONS
Clamping Level
..............................................................................................
260V
Capacitance
......................................................................................
30pf (approx.)
Suppression Modes
...........................................................
Metallic & Longitudinal
Wires Protected
....................................................................
2 wire/ 1 pr. (pins 4,5)
Fuseless/Auto-Resetting
..................................................................................
YES
Connections
............................................................................................
RJ-11/45
Clamping Level
................................................................................................
27V
Attenuation
..............................................................
<1 dB from 950MHz - 2.05GHz
<2.4 dB up to 2.2GHz
Shielded
...........................................................................................................
YES
Connections
......................................................................
Gold plated, Female “F”
Clamping Level
...............................................................................................
0.7V
Attenuation
................................................................
<1 dB from 50MHz -950MHz
Shielded
...........................................................................................................
YES
Connections
......................................................................
Gold plated, Female “F”
GENERAL
SATELLITE CIRCUIT
Connection
......................................................................................
1/8" mini-plug
Voltage and Polarity
.............................................................
12VDC, bi-directional
Current Requirement
.....................................................................................
30mA
DC TRIGGER
ANT/CATV CIRCUIT
TELEPHONE CIRCUIT
NOISE FILTRATION:
Filtered Outlet Banks
........................................................
55 dB (100 KHz - 1 MHz)
High-Current Outlets
.......................................................
50 dB (100 KHz - 1 MHz)
SURGE PROTECTION:
UL 1449 Surge Suppression Rating
................................................................
330V
Protection Modes
.......................................................................
L - N, L - G, N - G
Initial Clamping Level
..........................................................
200V Peak, 141V Rms
Response Time
...............................................................................................
<1ns
Joule Rating
........................................................................................
1790 Joules
Peak Impulse Current
...............................................................................
65,000A
Catastrophic Surge Circuit
..............................................................................
YES
AC:
Line Voltage
...............................................................................................
120VAC
Max Current Rating
......................................................................
15A (1800 Watts)
Thermal Fuse
...................................................................................................
YES
Over/Under Voltage Protection
.........................................................................
YES
Over-voltage shutoff threshold
................................................................
132V
Under-voltage shutoff threshold
................................................................
90V
AC CIRCUIT
Dimensions
.......................................................
17.25” W x 12” D x 3.5” H
Weight
.............................................................................................
16 lbs.
CONTACTING PANAMAX
For product and warranty information, dealer information, and other general information contact
Customer Relations at:
Email:
www.panamax.com
Fax
415-472-5540
800-472-5555
or
415-499-3900
, 7:30 a.m.- 5 p.m. PST
Design and specifications subject to change without notice due to product improvement.