Panamax M4300-EX Manual - Page 3

M4300 -EX Back Panel Connection Features, M4300 -EX Front Panel Features - power conditioner

Page 3 highlights

M4300 -EX Front Panel Features Power Button Press and hold for 2 seconds to turn Bank 2 outlets ON or OFF. Power LEDs Indicates the status of the rear panel outlets. LEDs for each outlet bank will be lit when the outlets are turned ON. They will flash during the startup and shutdown process. Unsafe Voltage Indicator Normally Off. Flashes to indicate that the incoming line voltage is unsafe and the unit has disconnected the power to protect your equipment. M4300-EX BANK 1 ALWAYS ON BANK 2 ON POWER AND FILTRATION WIRING OK UNSAFE VOLTAGE Wiring OK LED Normally On. Indicates that the wall outlet is properly grounded and Line/Neutral polarity is correct. Home Theater Power Conditioner M4300 -EX Back Panel Connection Features Circuit Breaker Automatically opens when the current load is greater than 15 Amps. Push to reset. Outlet Bank 1 Four always on outlets. Power will only be turned off under a fault condition. (See specifications for over-voltage and under-voltage thresholds) The High Current outlet provides power from a non-inductive noise filtration circuit that does not limit the current to your equipment. Its output is noise isolated from all of the other outlets. Power from the other three always on outlets is cleaned by a twostage tapped Pi filter circuit which provides noise isolation from both the High Current outlet and Outlet Bank 2. Outlet Bank 2 Four switched outlets controlled by the front panel Power Button. EMI/RFI noise filtration is provided by a two stage tapped Pi filter circuit which also provides noise isolation from all four outlets in Bank 1. Satellite TV Coax Jacks Bidirectional protection circuit optimized for satellite TV signal lines. Do not use for cable TV off-air antennas and cable modems. Cable TV Coax Jacks Bidirectional protection circuit optimized for cable TV, off-air antennas and cable modem signal lines. Do not use for Satellite TV. MAIN POWER 120 VAC/15A 15 AMP CIRCUIT BREAKER GROUND LUG HIGH CURRENT BANK 1 ALWAYS ON BANK 2 SWITCHED SUB / RECEIVER DVR HDTV / MONITOR HD CABLE / SAT DVD DIGITAL RADIO CD AUX / VCR 10/100bT LAN AND PHONE LINE IN EQUIP. 1 EQUIP. 2 LAN TEL SATELLITE CATV / ANT Main Power Must be plugged into a properly wired & grounded 3-wire outlet Ground Lug Provides a common grounding point for equipment with separate ground leads. LAN / Phone Jacks Protection circuits for 10/100 baseT Ethernet and standard telephone or pay-per-view lines. Phone circuit is auto-resetting. Incoming LAN or phone cords MUST be plugged into the LINE jack. Patch cords to the equipment (satellite receiver, digital video recorder, telephone, etc.) MUST be plugged into the EQUIP jacks.. Note to CATV Installers: This reminder is provided to call attention to Article 820-40 of the NEC. That article provides specific guidelines for proper grounding.It specifies that the cable ground shall be connected to the grounding system of the building and as close to the point of entry as practical.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

SATELLITE
CATV / ANT
MAIN POWER
120 VAC/15A
15 AMP
CIRCUIT
BREAKER
HIGH CURRENT
SUB / RECEIVER
BANK 1
ALWAYS ON
BANK 2
SWITCHED
DVR
HDTV / MONITOR
HD CABLE / SAT
DVD
DIGITAL RADIO
CD
AUX / VCR
GROUND
LUG
10/100bT LAN
AND
PHONE
LINE IN
EQUIP. 1
EQUIP. 2
LAN
TEL
POWER AND FILTRATION
BANK 1
ALWAYS ON
BANK 2
ON
WIRING
OK
UNSAFE
VOLTAGE
Home Theater Power Conditioner
M4300-EX
Power Button
Press and hold for 2 sec-
onds to turn Bank 2 out-
lets ON or OFF.
Power LEDs
Indicates the status of the rear panel
outlets.
LEDs for each outlet bank
will be lit when the outlets are turned
ON.
They will flash during the start-
up and shutdown process.
Circuit Breaker
Automatically opens
when the current load
is greater than 15
Amps.
Push to reset.
Ground Lug
Provides a common
grounding point for
equipment with sep-
arate ground leads.
Main Power
Must be plugged
into a properly
wired & ground-
ed 3-wire outlet
Wiring OK LED
Normally On.
Indicates
that the wall outlet is
properly grounded and
Line/Neutral polarity is
correct.
Outlet Bank 1
Four always on outlets.
Power will only be turned off under a fault
condition.
(See specifications for over-voltage and under-voltage
thresholds)
The
High Current outlet
provides power from a non-inductive
noise filtration circuit that does not limit the current to your equip-
ment.
Its output is noise isolated from all of the other outlets.
Power from the other three always on outlets is cleaned by a two-
stage tapped Pi filter circuit which provides noise isolation from
both the High Current outlet and Outlet Bank 2.
Outlet Bank 2
Four switched outlets
controlled by the front panel
Power Button.
EMI/RFI noise filtration is provided by a
two stage tapped Pi filter circuit which also provides
noise isolation from all four outlets in Bank 1.
LAN / Phone Jacks
Protection circuits for 10/100
baseT Ethernet and standard tele-
phone
or
pay-per-view
lines.
Phone circuit is auto-resetting.
Incoming LAN or phone cords
MUST
be plugged into the
LINE
jack.
Patch cords to the equipment
(satellite receiver, digital video
recorder, telephone, etc.)
MUST
be
plugged into the
EQUIP
jacks..
Satellite TV Coax Jacks
Bidirectional protection cir-
cuit optimized for satellite TV
signal lines.
Do not use for
cable TV off-air antennas
and cable modems.
Cable TV Coax Jacks
Bidirectional protection cir-
cuit optimized for cable TV,
off-air antennas and cable
modem signal lines.
Do not
use for Satellite TV.
M4300 -EX Back Panel Connection Features
M4300 -EX Front Panel Features
Note to CATV Installers:
This reminder is provided to call attention to Article 820-40 of the NEC.
That article provides specific
guidelines for proper grounding.It specifies that the cable ground shall be connected to the grounding
system of the building and as close to the point of entry as practical.
Unsafe Voltage Indicator
Normally Off.
Flashes to indicate that the incoming
line voltage is unsafe and the unit has disconnected
the power to protect your equipment.