NEC NP-PA1705UL-B RS232 codes- Projectors - Page 74

Information, For the values of the Sub input setting value

Page 74 highlights

Response  When the command succeeds 23h B0h 03h C5h Data part Item DATA01 DATA02 Description Target 00h MODE 01h START POSITION 02h SUB INPUT / SUB INPUT 1 09h SUB INPUT 2 0Ah SUB INPUT 3 Setting value (when DATA01 is 00h "MODE") 00h PIP 01h PICTURE BY PICTURE Setting value (when DATA01 is 01h "START POSITION") 00h TOP-LEFT 01h TOP-RIGHT 02h BOTTOM-LEFT 03h BOTTOM-RIGHT Sub input setting value (when DATA01 is 02h "SUB INPUT / SUB INPUT 1") Sub input setting value (when DATA01 is 09h "SUB INPUT 2") Sub input setting value (when DATA01 is 0Ah "SUB INPUT 3") Information For the values of the Sub input setting value, see the Appendix "Supplementary Information by Command".  When the command fails A3h B0h 02h ©NEC Display Solutions, Ltd. 2014-2020 74

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87

©NEC Display Solutions, Ltd. 2014-2020
74
Response
When the command succeeds
23h
B0h
<ID1>
<ID2>
03h
C5h
<DATA01>
<DATA02>
<CKS>
Data part
Item
Description
DATA01
Target
00h
MODE
01h
START POSITION
02h
SUB INPUT / SUB INPUT 1
09h
SUB INPUT 2
0Ah
SUB INPUT 3
DATA02
Setting value (when DATA01 is 00h "MODE")
00h
PIP
01h
PICTURE BY PICTURE
Setting value (when DATA01 is 01h "START POSITION")
00h
TOP-LEFT
01h
TOP-RIGHT
02h
BOTTOM-LEFT
03h
BOTTOM-RIGHT
Sub input setting value (when DATA01 is 02h "SUB INPUT / SUB INPUT 1")
Sub input setting value (when DATA01 is 09h "SUB INPUT 2")
Sub input setting value (when DATA01 is 0Ah "SUB INPUT 3")
Information
For the values of the Sub input setting value, see the Appendix "Supplementary Information by Command".
When the command fails
A3h
B0h
<ID1>
<ID2>
02h
<ERR1>
<ERR2>
<CKS>