Installation To Wood Joist Finished Ceilings, Exposed Wood Joists, or, Wood Beam Ceilings - mount

Page 4 highlights

Installation To Wood Joist Finished Ceilings, Exposed Wood Joists, or Wood Beam Ceilings WARNING • Tighten wood screws (F) so that ceiling plate (G) is firmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power. • Never tighten in excess of 80 in • lb (9 N.M.). • Make sure that mounting screws are anchored into the center of the studs. The use of an "edge to edge" stud finder is highly recommended. 1 Drill two 5/32" (4 mm) dia. holes to a minimum depth of 2.5" (64 mm). Attach ceiling plate (G) with two #14 x 2.5" (6 mm x 65 mm) wood screws (F) as shown using 3/8" (10 mm) socket wrench. Skip to step 2. WOOD JOIST CEILING WARNING • It is the responsibility of the installer to verify that the G supporting surface will safely support the combined load of all attached hardware and components. IMPORTANT: Be sure to drill holes into the joist CENTER! F F WOOD JOIST CEILING For optional Cord Management, install two spacers (H) between ceiling plate (G) and ceiling. H H G F F Visit the Peerless Web Site at www.peerlessmounts.com 4 of 9 ISSUED: 04-11-06 SHEET #: 055-9458-6 09-25-09 For customer care call 1-800-729-0307 or 708-865-8870.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9

ISSUED: 04-11-06
SHEET #: 055-9458-6
09-25-09
Visit the Peerless Web Site at www.peerlessmounts.com
4 of 9
For customer care call 1-800-729-0307 or 708-865-8870.
F
F
G
WOOD
JOIST
CEILING
Drill two 5/32" (4 mm) dia. holes to a minimum
depth of 2.5" (64 mm). Attach ceiling plate (
G
)
with two #14 x 2.5" (6 mm x 65 mm) wood
screws (
F
) as shown using 3/8" (10 mm) socket
wrench.
Skip to step 2.
IMPORTANT: Be sure to drill holes into the
joist
CENTER!
For optional Cord Management,
install two spacers (
H
) between ceiling
plate (
G
) and ceiling.
Installation To Wood Joist Finished Ceilings, Exposed Wood Joists, or
Wood Beam Ceilings
WOOD
JOIST
CEILING
F
F
G
H
H
Tighten wood screws (
F
) so that ceiling plate (
G
) is firmly attached, but do not overtighten. Overtightening can damage
the screws, greatly reducing their holding power.
Never tighten in excess of 80 in • lb (9 N.M.).
Make sure that mounting screws are anchored into the center of the studs. The use of an "edge to edge" stud finder is
highly recommended.
WARNING
It is the responsibility of the installer to verify that the
supporting surface will safely support the combined
load of all attached hardware and components.