NEC NP-ME372W RS232 codes- Projectors - Page 82
[ 305-2. SERIAL NUMBER REQUEST ], Command, Response, When the command succeeds, Data part,
View all NEC NP-ME372W manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 82 highlights
3.51 [ 305-2. SERIAL NUMBER REQUEST ] Gets the serial number of the projector. Command 00h BFh 00h 00h 02h 01h 06h C8h Response When the command succeeds 20h BFh 12h 01h 06h - Data part Item DATA01 - 16 Description Serial number (NUL: termination character string) When the command fails A0h BFh 02h ©NEC Display Solutions, Ltd. 2014-2020 82
-
1
-
2
-
3
-
4
-
5
-
6
-
7
-
8
-
9
-
10
-
11
-
12
-
13
-
14
-
15
-
16
-
17
-
18
-
19
-
20
-
21
-
22
-
23
-
24
-
25
-
26
-
27
-
28
-
29
-
30
-
31
-
32
-
33
-
34
-
35
-
36
-
37
-
38
-
39
-
40
-
41
-
42
-
43
-
44
-
45
-
46
-
47
-
48
-
49
-
50
-
51
-
52
-
53
-
54
-
55
-
56
-
57
-
58
-
59
-
60
-
61
-
62
-
63
-
64
-
65
-
66
-
67
-
68
-
69
-
70
-
71
-
72
-
73
-
74
-
75
-
76
-
77
-
78
-
79
-
80
-
81
-
82
-
83
-
84
-
85
-
86
-
87
©NEC Display Solutions, Ltd. 2014-2020
82
3.51
[ 305-2. SERIAL NUMBER REQUEST ]
Gets the serial number of the projector.
Command
00h
BFh
00h
00h
02h
01h
06h
C8h
Response
When the command succeeds
20h
BFh
<ID1>
<ID2>
12h
01h
06h
<DATA01>
-
<DATA16>
<CKS>
Data part
Item
Description
DATA01 - 16
Serial number (NUL: termination character string)
When the command fails
A0h
BFh
<ID1>
<ID2>
02h
<ERR1>
<ERR2>
<CKS>