NEC NP-ME361W RS232 codes- Projectors - Page 35
Power Off inhibited.
View all NEC NP-ME361W manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 35 highlights
DATA02 Results 00H : Normal 01H : Error Response: At the time of a failure A3H B1H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 6. Response At the time of a success( ACK ) This returns ACK without adding data portion to the command that does not request data. This returns ACK with adding data to the data portion for the command that requests data. * At the time of a failure( NAK ) This adds a cause of not accepting the command to data portion to return it. (Example) Power On Command: 02H 00H 00H 00H 00H CKS Response: A2H 00H 01H 40H 02H DATA01 DATA02 CKS 7. Table of Response Error Codes DATA01 DATA2 Error Error Types description 00H 00H 00H 01H 01H 00H 01H 01H 02H 03H 02H 0DH Error contents Unknown command. This current model does not support this function. Invalid values specified. Specified terminal is unavailable or cannot be selected. Setting not possible. Power Off inhibited. 050. REMOTE KEY CODE Function: This command sends remote control key codes of projector. Command: 02H 0FH 00H 00H 02H DATA01 DATA02 CKS (*3) Data Portion Contents