NEC NP-ME331X RS232 codes- Projectors - Page 33
NEC NP-ME331X Manual
View all NEC NP-ME331X manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 33 highlights
(!1) X = 100 - ((Lamp Use Prohibited Time * 100) / Lamp Use Warning Starting Time) Example) The case of Lamp Use Prohibited Time 2100[H] A Lamp Use Warning Starting Time 2000[H] Model. X = 100 - ((2100 * 100) / 2000) = -5[%] (!2) Lamp Hour Meter This is the timer for normal lamp mode conversion. (!3) Lamp usage time This is the lamp total usage. It is displayed in the projector's menu. (!4) This setting is ignored, if the Item's unit is not time. (!5) NP4000/4001, NP4100/4100W : This function is not supported. 038. LAMP MODE REQUEST Function: This command acquires the setting of the lamp mode of projector. Command: 03H B0H 00H 00H 01H 07H BBH Response: At the time of a success 23H B0H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*3) Data Portion Contents DATA01 07H fixed DATA02 Setting Value 00H : Normal 01H : Eco Response: At the time of a failure A3H B0H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 039. LAMP MODE SET Function: This command sets the lamp mode of projector. Command: 03H B1H 00H 00H 02H DATA01 DATA02 CKS (*3) Data Portion Contents DATA01 07H fixed DATA02 Setting Value 00H : Normal 01H : Eco Response: At the time of a success 23H B1H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*3) Data Portion Contents