NEC NP-ME301W RS232 codes- Projectors - Page 8
H : Parameter error
View all NEC NP-ME301W manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 8 highlights
* Data portion This becomes data of data length specified in the data length portion. Command : This sets data added to a command to send it. ( See each command description.) Response : This sets data added to a response to send it. ( See each command description.) * Checksum This is lower ranking 8 bits of the sum total of the header and data portions of one transmit and receive data frame. 4-2. Data portion of response For ACK This returns ACK without adding data portion to the command that does not request data. This returns ACK with adding data to the data portion for the command that requests data. For NAK This adds a cause of not accepting the command to data portion to return it. (Example) Power On Command: 02H 00H FFH F0H 00H CKS NAK: A2H 00H 01H 20H 02H DATA01 DATA02 CKS Data Contents DATA01 Error types 00H : Not supported 01H : Parameter error 02H : Operation mode error 03H : Gain-related error 04H : Logo transfer error DATA02 Error description * When not supported 00H : Unknown command 01H : The current model does not support this function. 02H : This model is not compatible with the Switcher. 03H : This model is not compatible with the PC Viewer. * When a parameter error occurs 00H : Unvalid values specified. 01H : Specified terminal is unavailable or cannot be selected 02H : Selected language is not available. * When an operation mode error occurs 00H : Available memory reservation error