Marantz SR8015 HEOS CLI ProtocolSpecification Version - Page 8
Command and Response Details
View all Marantz SR8015 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 8 highlights
Note: Special characters '&', '=', and '%' in the JSON response fields are encoded to '%26(&)', '%3D(=)', and '%25(%)'. 4. Command and Response Details 4.1 System Commands 4.1.1 Register for Change Events By default HEOS speaker does not send Change events. Controller needs to send this command with enable=on when it is ready to receive unsolicit responses from CLI. Please refer to "Driver Initialization" section regarding when to register for change events. Command: heos://system/register_for_change_events?enable='on_or_off' Attribute Description Enumeration enable Register or unregister for change events. on,off Response: { "heos": { "command": "system/register_for_change_events", "result": "success", "message": "enable='on_or_off'" } } Example: heos://system/register_for_change_events?enable=on 4.1.2 HEOS Account Check Command: heos://system/check_account This command returns current user name in its message field if the user is currently singed in. Response: { "heos": { "command": "system/check_account", "result": "success", "message": "signed_out" or "signed_in&un=" } } Example: heos://system/check_account 4.1.3 HEOS Account Sign In Command: heos://system/sign_in?un=heos_username&pw=heos_password Attribute Description Enumeration un HEOS account username N/A pw HEOS account password N/A Response: { "heos": { "command": "system/sign_in ", "result": "success", "message": "signed_in&un=" } }