INTRODUCTION OPERATOR SPECIFICATIONS This model is intended for use in vehicular slide gate applications: Usage Classification Accessory Power Maximum Gate Weight Minimum Gate Travel Distance Maximum Gate Travel Distance Maximum Gate Travel Speed Maximum Daily Cycle Rate Maximum Duty Cycle Operating Temperature Expansion Board Inherent Entrapment Protection (Type A) External Entrapment Protection (Type B1 and/or Type B2) Class I, II, III, and IV Main Control Board: 24 Vac, 500 mA max. Terminal Strip: 24 Vac, 2.2 A max. for 120/208-240 Vac, Single Phase and 208-240/480 Vac, Three Phase 24 Vac, 1.3 A max. for 575 Vac, Three Phase 1 HP (1 Phase and 3 Phase): 1700 lbs. 1-1/2 HP (1 Phase): 2100 lbs. 2 HP (3 Phase): 2500 lbs. 4 feet (1.2 m) 1 HP (1 Phase and 3 Phase): Cantilever 35 feet OH Roller 70 feet V-Track 50 feet 1-1/2 HP (1 Phase): Cantilever 40 feet OH Roller 80 feet V-Track 55 feet 2 HP (3 Phase): Cantilever 45 feet OH Roller 90 feet V-Track 60 feet 1 foot/second Continuous Continuous Without Heater: -20°C to 60°C (-4°F to 140°F) With Optional Heater: -40°C to 60°C (-40°F to 140°F) Provided RPM 3 inputs per board - any combination of up to 3 photoelectric sensors and up to 2 edge sensors 30" (76.2 cm) 35.4" (89.9 cm) 6 16.4" (41.7 cm)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

6
OPERATOR SPECIFICATIONS
This model is intended for use in vehicular slide gate applications:
INTRODUCTION
Usage Classification
Class I, II, III, and IV
Accessory Power
Main Control Board:
24 Vac, 500 mA max.
Terminal Strip:
24 Vac, 2.2 A max. for 120/208-240 Vac, Single Phase and 208-240/480 Vac, Three Phase
24 Vac, 1.3 A max. for 575 Vac, Three Phase
Maximum Gate Weight
1 HP (1 Phase and 3 Phase):
1700 lbs.
1-1/2 HP (1 Phase):
2100 lbs.
2 HP (3 Phase):
2500 lbs.
Minimum Gate Travel Distance
4 feet (1.2 m)
Maximum Gate Travel Distance
1 HP (1 Phase and 3 Phase):
Cantilever
...................................
35 feet
OH Roller
...................................
70 feet
V-Track
......................................
50 feet
1-1/2 HP (1 Phase):
Cantilever
..................................................
40 feet
OH Roller
..................................................
80 feet
V-Track
.....................................................
55 feet
2 HP (3 Phase):
Cantilever
........................................................
45 feet
OH Roller
........................................................
90 feet
V-Track
...........................................................
60 feet
Maximum Gate Travel Speed
1 foot/second
Maximum Daily Cycle Rate
Continuous
Maximum Duty Cycle
Continuous
Operating Temperature
Without Heater: -20°C to 60°C (-4°F to 140°F)
With Optional Heater: -40°C to 60°C (-40°F to 140°F)
Expansion Board
Provided
Inherent Entrapment Protection
(Type A)
RPM
External Entrapment Protection
(Type B1 and/or Type B2)
3 inputs per board - any combination of up to 3 photoelectric sensors and up to 2 edge sensors
35.4" (89.9 cm)
30" (76.2 cm)
16.4" (41.7 cm)