LiftMaster SL3000UL SL3000UL ADDENDUM Manual - Page 5

Solenoid Brake Description, Optional Factory Installed DC2000 Backup System, Solenoid Brake Engaged - sl3000uldc

Page 5 highlights

Solenoid Brake Description Brake will keep spoked pulley from moving when engaged. Brake MUST be disengaged to manually push gate open (Backdriven). Connected to 120 Vac Only NO DC2000 Backup Brake Power (See Important below) Solenoid Brake Disengaged Solenoid Brake Engaged • Operator's normal gate cycle. • AC power failure. • Stop/Reset button has been pressed ONLY once. • Gate in closed position with normal AC power. • Stop/Reset button has been pressed twice. Optional Factory Installed DC2000 Backup System Opens or closes the gate with dedicated devices wired directly to the DC2000 when the AC power fails at the operator. (Refer to pages 30 through 32 in the manual) WARNING To reduce the risk of INJURY, dedicated devices MUST be far enough from the gate so that the user is prevented from coming in contact with the gate while operating the controls. IMPORTANT The DC2000 WILL NOT operate an Emergency Key Switch (Knox Box) wired to the operator's surge suppressor when the AC power fails at the operator. If this AC power failure occurs, the solenoid brake will be disengaged regardless of the DC2000's battery power . The gate can be manually pushed opened at any time as long as there is NO AC power at the operator. (See above and Fire/Police Key Access Addendum Page 5) Contact your local municipalities for more information CLASS I, II, III, IV on correct emergency vehicle access operator installation and procedures. Addendum Page 4 SL3000ULDCE™

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

WARNING
IMPORTANT
To reduce the risk of INJURY, dedicated devices MUST be far enough from the gate so that
the user is prevented from coming in contact with the gate while operating the controls.
Solenoid Brake Engaged
Solenoid Brake Disengaged
Connected to
120 Vac Only
NO
DC2000 Backup Brake Power
(See
Important
below)
• Operator’s normal gate cycle.
• AC power failure.
• Stop/Reset button has been pressed
ONLY
once
.
• Gate in closed position with normal AC power.
• Stop/Reset button has been pressed
twice
.
Solenoid Brake Description
Brake will keep spoked pulley from moving when engaged. Brake
MUST
be disengaged
to manually push gate open (Backdriven).
Opens or closes the gate with
dedicated devices
wired directly to the DC2000 when the
AC power fails at the operator. (Refer to pages 30 through 32 in the manual)
The DC2000
WILL NOT
operate an Emergency Key Switch (Knox
Box) wired to the operator’s surge suppressor when the AC power
fails at the operator.
If this AC power failure occurs,
the solenoid brake will be disen-
gaged regardless of the DC2000’s battery power
. The gate can
be manually pushed opened at any time as long as there is
NO
AC
power at the operator.
(See above and Fire/Police Key Access
Addendum Page 5
)
Contact your local municipalities for more information
on correct emergency vehicle access operator installa-
tion and procedures.
Optional Factory Installed DC2000 Backup System
Addendum Page 4
CLASS I, II, III, IV
SL3000ULDCE™