LiftMaster SL3000501U SL3000501U Installation Manual - Page 33

Field Wiring, Additional Wiring

Page 33 highlights

ADDITIONAL WIRING To protect against fire and electrocution: • DISCONNECT power BEFORE installing or servicing operator. For continued protection against fire: • Replace ONLY with fuse of same type and rating. FIELD WIRING BIPART DELAY 4 2 6 OPEN LEFT OPEN 8 RIGHT HANDING CONTROL BOARD GND ANTENNA CURRENT MOTOR DRIVE SENSOR ID RESET RPM & LIMITS ALARM EXP. BOARD 24 VAC IN CLASS 2 SUPPLY 24 VAC 500 mA MAX COMM LINK BA + + 3-BUTTON + CONTROL - N.C. STATION - + FIRE DEPARTMENT - INTERRUPT LOOP or + EXIT LOOP PHOTOELECTRIC SENSORS for CLOSE cycle - + SHADOW LOOP - + - + - + N.C. COM N.O. - ACCESSORY + POWER 24 Vac 500 mA Maximum EDGE SENSOR for CLOSE cycle EDGE SENSOR or PHOTOELECTRIC SENSORS for OPEN cycle Shielded Twisted Pair Cable (Primary/Secondary link to other gate operator) Ground the shield of the cable to the chassis ground of each operator. Solenoid Lock (Optional) Maglock (Optional) OR (Not Provided) PLUG-IN LOOP DETECTOR Model LOOPDETLM EXPANSION BOARD POWER NOTE: These switches determine if the corresponding photoelectric sensor or edge sensor will function for the OPEN or CLOSE cycle. (Not Provided) HEATER TO MAIN BOARD SHADOW INTERUPT EXIT INTERRUPT LOOP SHADOW LOOP OPEN CLOSE 1 EYE ONLY 2 EYE/ EDGE 3 EYE/ EDGE COM SBC OPN CLS STP COM + + + - + + + + - N.C. PHOTOELECTRIC SENSORS PHOTOELECTRIC SENSORS or EDGE SENSORS SINGLE BUTTON CONTROL STATION 3-BUTTON CONTROL STATION JUNCTION BOX N.C. COM N.O. N.C. COM N.O. NOTE: These switches control how the Auxiliary Relays will function. AUXILIARY AUXILIARY RELAY 1 RELAY 2 GND N L EXIT LOOP Incoming Power 31

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

31
N.O.
COM
N.C.
N.O.
COM
N.C.
SHADOW
INTERUPT
EXIT
SBC
OPN
CLS
STP
COM
EYE
ONLY
EYE/
EDGE
EYE/
EDGE
COM
1
2
3
OPEN
CLOSE
TO MAIN
BOARD
POWER
COMM
LINK
B
A
ANTENNA
CURRENT
SENSOR
MOTOR DRIVE
RPM & LIMITS
ALARM
EXP.
BOARD
24 VAC IN
CLASS 2 SUPPLY
24 VAC
500 mA MAX
ID RESET
GND
BIPART
DELAY
2
4
6
8
OPEN
LEFT
OPEN
RIGHT
HANDING
+
+
+
+
+
+
+
N.C.
N.O.
COM
+
+
+
+
+
+
+
+
+
+
Maglock
(Optional)
Solenoid Lock
(Optional)
OR
Shielded Twisted Pair Cable (Primary/Secondary
link to other gate operator) Ground the shield of the
cable to the chassis ground of each operator.
ACCESSORY
POWER
24 Vac 500 mA
Maximum
(Not Provided)
(Not Provided)
N.C.
INTERRUPT LOOP
or
PHOTOELECTRIC SENSORS
for CLOSE cycle
EDGE SENSOR
for CLOSE cycle
EDGE SENSOR
or
PHOTOELECTRIC
SENSORS
for OPEN cycle
SHADOW LOOP
EXIT LOOP
FIRE DEPARTMENT
3-BUTTON
CONTROL
STATION
CONTROL BOARD
HEATER
SHADOW LOOP
EXIT LOOP
INTERRUPT
LOOP
AUXILIARY
RELAY 2
AUXILIARY
RELAY 1
SINGLE BUTTON
CONTROL STATION
3-BUTTON
CONTROL STATION
PHOTOELECTRIC SENSORS
PHOTOELECTRIC SENSORS
or
EDGE SENSORS
NOTE:
These switches determine if the
corresponding photoelectric sensor or edge
sensor will function for the OPEN or CLOSE cycle.
PLUG-IN LOOP DETECTOR
Model LOOPDETLM
NOTE:
These switches control how
the Auxiliary Relays will function.
EXPANSION BOARD
JUNCTION BOX
L
N
GND
Incoming Power
N.C.
To protect against fire and electrocution:
DISCONNECT power BEFORE installing or servicing operator.
For continued protection against fire:
Replace ONLY with fuse of same type and rating.
ADDITIONAL WIRING
FIELD WIRING