LiftMaster RSL12V RSL12V Installation Manual - Page 14

» Power Wiring + Connect Batteries - accessories

Page 14 highlights

WIRING » POWER WIRING + CONNECT BATTERIES POWER WIRING SOLAR PANEL (NOT PROVIDED. SEE ACCESSORIES.) 3 The solar panel(s) must be located in an open area clear of obstructions and shading for the entire day. The gate operator is not supported in northern climates where temperatures reach below -4˚F. This is due to cold weather and a 2 reduced number of hours of sunlight during the winter months. Cycle rate may vary from solar chart for areas that reach below 32˚F. Solar panels should be cleaned on a regular basis for best performance to ensure proper operation. For solar applications, a minimum of 20W solar panels and two 7AH batteries are recommended. For Zone 3 cold weather sites, one 33AH battery is recommended. We recommend LiftMaster low power draw accessories to minimize power draw, refer to accessory page. NOT AVAILABLE 1 2 NUMBER OF CYCLES PER DAY 3 1 NOT AVAILABLE 1 Single Gate Installations (16 ft. 650 lb. gate) Accessories Zone 1 Zone 2 Zone 3 (6 Hrs sunlight/day) (4 Hrs Sunlight/day) (2 Hrs Sunlight/day) Dual Gate Installations (16 ft. 650 lb. gate) Accessories Zone 1 Zone 2 Zone 3 (6 Hrs sunlight/day) (4 Hrs Sunlight/day) (2 Hrs Sunlight/day) Solenoid Lock 50 mA 100 mA 300 mA 2 7AH Batteries (optional) 1 33AH Battery (optional) 2 7AH Batteries (optional) 1 33AH Battery (optional) 1 33AH Battery (optional) Solenoid Lock 50 mA 100 mA 300 mA 2 7AH Batteries (optional) 1 33AH Battery (optional) 2 7AH Batteries (optional) 1 33AH Battery (optional) 1 33AH Battery (optional) 20W SOLAR PANEL 30W SOLAR PANEL 50 50 ✔ 48 50 ✔ 50 50 ✔ 41 49 ✔1 9 50 50 ✔ 50 50 ✔ 50 50 ✔ 50 50 ✔ 30 43 38 43 32 36 30 35 21 26 0 0 50 50 48 50 50 50 41 50 1 9 20 17 12 3 0 31 26 24 15 0 20W SOLAR PANEL 30W SOLAR PANEL 25 29 ✔ 23 27 ✔ 22 26 ✔ 18 22 ✔0 4 39 45 ✔ 35 41 ✔ 35 41 ✔ 31 37 ✔ 13 19 17 19 15 17 13 15 9 12 0 0 25 29 23 27 22 26 18 22 0 4 CONNECT BATTERIES The batteries are charged in the circuit by using the transformer (provided) or an optional solar panel. Batteries will degrade over time depending on temperature and usage. For best performance, the batteries should be replaced every 3 years. Batteries do not perform well in extremely cold temperatures. The operator comes with one 7AH battery. A second 7AH (29-NP712) battery may be added or one 33AH (A12330SGLPK) may be used in place of the 7AH batteries. NOTE: There may not be sufficient mounting space for the 33AH battery if a heater is installed. Connector Battery Plug Always disconnect the batteries BEFORE servicing the operator. NOTE: Setting the battery on concrete will not have a negative affect on the charging or battery life. 1 If the installation is a dual gate, proceed to next page. 21 Locate the battery plug. Connect the battery plug to either connector on the control board. Provided NUMBER OF CYCLES FOR BATTERY BACKUP 9 8 5 1 0 14 13 10 6 0 2 Optional (not provided) Accessories Single Gate (16 ft. 650 lb. gate) Accessories Dual Gate (16 ft. 650 lb. gate) Solenoid Lock 50 mA 100 mA 300 mA 1 7AH Battery (standard) 2 7AH Batteries (optional) 1 33AH Battery (optional) Solenoid Lock 50 mA 100 mA 300 mA 1 7AH Battery (standard) 2 7AH Batteries (optional) 1 33AH Battery (optional) BATTERY BACKUP (BBU) ✔ ✔ ✔ 40 36 43 42 100 83 98 97 275 228 269 267 BATTERY BACKUP (BBU) ✔ ✔ ✔ 19 17 19 19 44 40 44 43 121 111 121 120 ✔ 41 94 258 ✔ 19 43 118 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

WIRING
» POWER WIRING + CONNECT BATTERIES
CONNECT BATTERIES
The batteries are charged in the circuit by using the transformer (provided) or an
optional solar panel. Batteries will degrade over time depending on temperature and
usage. For best performance, the batteries should be replaced every 3 years.
Batteries do not perform well in extremely cold temperatures. The operator comes
with one 7AH battery. A second 7AH (29-NP712) battery may be added or one
33AH (A12330SGLPK) may be used in place of the 7AH batteries.
NOTE:
There may
not be sufficient mounting space for the 33AH battery if a heater is installed.
Always
disconnect the batteries BEFORE servicing the operator.
NOTE:
Setting the battery on concrete will not have a negative affect on the
charging or battery life.
If the installation is a dual gate, proceed to next page.
Locate the battery plug.
Connect the battery plug to either connector on the control board.
1
Battery
Plug
Connector
2
NOT AVAILABLE
NOT AVAILABLE
1
1
1
2
3
3
2
POWER WIRING
SOLAR PANEL (NOT PROVIDED. SEE ACCESSORIES.)
The solar panel(s) must be located in an open area clear of obstructions
and shading for the entire day.
The gate operator is not supported in northern
climates where temperatures reach below -4˚F. This is due to cold weather and a
reduced number of hours of sunlight during the winter months. Cycle rate may vary
from solar chart for areas that reach below 32˚F. Solar panels should be cleaned on
a regular basis for best performance to ensure proper operation. For solar
applications, a minimum of 20W solar panels and two 7AH batteries are
recommended. For Zone 3 cold weather sites, one 33AH battery is recommended.
We recommend LiftMaster low power draw accessories to minimize power draw,
refer to accessory page.
Accessories Zone 1
Zone 2
Zone 3
(6 Hrs sunlight/day)
(4 Hrs Sunlight/day)
(2 Hrs Sunlight/day)
20W
SOLAR
PANEL
30W
SOLAR
PANEL
50
50
38
43
20
48
50
32
36
17
50
50
30
35
12
41
49
21
26
3
1
9
0
0
0
50
50
50
50
31
50
50
48
50
26
50
50
50
50
24
50
50
41
50
15
30
43
1
9
0
NUMBER OF CYCLES PER DAY
Single Gate Installations (16 ft. 650 lb. gate)
Solenoid Lock
50 mA
100 mA
300 mA
2 7AH Batteries (optional)
1 33AH Battery (optional)
2 7AH Batteries (optional)
1 33AH Battery (optional)
1 33AH Battery (optional)
25
29
17
19
9
23
27
15
17
8
22
26
13
15
5
18
22
9
12
1
0
4
0
0
0
39
45
25
29
14
35
41
23
27
13
35
41
22
26
10
31
37
18
22
6
13
19
0
4
0
Solenoid Lock
50 mA
100 mA
300 mA
2 7AH Batteries (optional)
1 33AH Battery (optional)
2 7AH Batteries (optional)
1 33AH Battery (optional)
1 33AH Battery (optional)
20W
SOLAR
PANEL
30W
SOLAR
PANEL
Dual Gate Installations (16 ft. 650 lb. gate)
Accessories Zone 1
Zone 2
Zone 3
(6 Hrs sunlight/day)
(4 Hrs Sunlight/day)
(2 Hrs Sunlight/day)
Provided
Optional
(not provided)
Accessories
Single Gate (16 ft. 650 lb. gate)
BATTERY
BACKUP
(BBU)
40
100
275
36
83
228
43
98
269
42
97
267
41
94
258
Solenoid Lock
50 mA
100 mA
300 mA
1 7AH Battery
(standard)
2 7AH Batteries
(optional)
1 33AH Battery
(optional)
Accessories
Dual Gate (16 ft. 650 lb. gate)
BATTERY
BACKUP
(BBU)
19
44
121
17
40
111
19
44
121
19
43
120
19
43
118
Solenoid Lock
50 mA
100 mA
300 mA
1 7AH Battery
(standard)
2 7AH Batteries
(optional)
1 33AH Battery
(optional)
NUMBER OF CYCLES FOR BATTERY BACKUP
1
2
13