LiftMaster JDC LiftMaster MAXUM Commercial Door Operator Overview - English - Page 31

TDC Trolley Operators

Page 31 highlights

TDC Trolley Operators Model Max Door Weight TDC7S1BMC 700 lbs. Voltage/Phase 120Vac 1 PH/240Vac 1/3PH* Equivalent Horsepower 1/2 HP TDC7S4BMC 700 lbs. 480Vac 3PH 1/2 HP TDC12S1BMC 1200 lbs. 120Vac 1 PH/240Vac 1/3PH* 3/4 HP TDC12S4BMC 1200 lbs. 480Vac 3PH 3/4 HP TDC12X1BMC 1200 lbs. 120Vac 1 PH/240Vac 1/3PH* 3/4 HP TDC12X4BMC 1200 lbs. 480Vac 3PH 3/4 HP TDC22X1BMC 2200 lbs. 120Vac 1 PH/240Vac 1/3PH* 1 and 1.5 HP TDC22X4BMC 2200 lbs. 480Vac 3PH 1 and 1.5 HP TDC12X1N4XMC 1200 lbs. 120Vac 1 PH/240Vac 1/3PH* 3/4 HP TDC12X4N4XMC 1200 lbs. 480Vac 3PH 3/4 HP TDC22X1N4XMC 2200 lbs. 120Vac 1 PH/240Vac 1/3PH* 1 and 1.5 HP TDC22X4N4XMC 2200 lbs. 480Vac 3PH 1/2 HP NOTE: Phase 1 is Q1 of 2024, Phase 2 is Q3 of 2024 and Phase 3 is Q1 of 2025. TDC maximum door height is up to 24 feet. *Convertible to 208Vac 3PH or 600Vac 3PH via transformer, ordered separately. **Extended Duty is formerly known as Heavy Industrial Duty or Gear Head. NEMA 4X - Yes Yes Yes Yes Extended Duty Standard Duty up to 90 Cycles a Day Standard Duty up to 90 Cycles a Day Standard Duty up to 90 Cycles a Day Standard Duty up to 90 Cycles a Day Extended Duty** up to 150 Cycles a Day Extended Duty** up to 150 Cycles a Day Extended Duty** up to 150 Cycles a Day Extended Duty** up to 150 Cycles a Day Extended Duty** up to 150 Cycles a Day Extended Duty** up to 150 Cycles a Day Extended Duty** up to 150 Cycles a Day Extended Duty** up to 150 Cycles a Day Launch Phase 1 1 1 1 1 1 2 2 3 3 3 3 29

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

Model
Max Door
Weight
Voltage/Phase
Equivalent
Horsepower
NEMA 4X
Extended Duty
Launch
Phase
TDC7S1BMC
700 lbs.
120Vac 1 PH/240Vac 1/3PH*
1²2 HP
-
Standard Duty
up to 90 Cycles a Day
1
TDC7S4BMC
700 lbs.
480Vac 3PH
1²2 HP
-
Standard Duty
up to 90 Cycles a Day
1
TDC12S1BMC
1200 lbs.
120Vac 1 PH/240Vac 1/3PH*
3²4 HP
-
Standard Duty
up to 90 Cycles a Day
1
TDC12S4BMC
1200 lbs.
480Vac 3PH
3²4 HP
-
Standard Duty
up to 90 Cycles a Day
1
TDC12X1BMC
1200 lbs.
120Vac 1 PH/240Vac 1/3PH*
3²4 HP
-
Extended Duty**
up to 150 Cycles a Day
1
TDC12X4BMC
1200 lbs.
480Vac 3PH
3²4 HP
-
Extended Duty**
up to 150 Cycles a Day
1
TDC22X1BMC
2200 lbs.
120Vac 1 PH/240Vac 1/3PH*
1 and 1.5 HP
-
Extended Duty**
up to 150 Cycles a Day
2
TDC22X4BMC
2200 lbs.
480Vac 3PH
1 and 1.5 HP
-
Extended Duty**
up to 150 Cycles a Day
2
TDC12X1N4XMC
1200 lbs.
120Vac 1 PH/240Vac 1/3PH*
3²4 HP
Yes
Extended Duty**
up to 150 Cycles a Day
3
TDC12X4N4XMC
1200 lbs.
480Vac 3PH
3²4 HP
Yes
Extended Duty**
up to 150 Cycles a Day
3
TDC22X1N4XMC
2200 lbs.
120Vac 1 PH/240Vac 1/3PH*
1 and 1.5 HP
Yes
Extended Duty**
up to 150 Cycles a Day
3
TDC22X4N4XMC
2200 lbs.
480Vac 3PH
1²2 HP
Yes
Extended Duty**
up to 150 Cycles a Day
3
TDC Trolley Operators
NOTE:
Phase 1 is Q1 of 2024, Phase 2 is Q3 of 2024 and Phase 3 is Q1 of 2025.
TDC maximum door height is up to 24 feet.
*Convertible to 208Vac 3PH or 600Vac 3PH via transformer, ordered separately.
**Extended Duty is formerly known as Heavy Industrial Duty or Gear Head.
29