LiftMaster CAPAC LiftMaster CAPAC Wiring Diagram - English French Spanish - Page 2

Gate Access, Status, Auxiliary Relay, Primary Relay

Page 2 highlights

Gate Access Not responsible for conflicts between the information listed in the wiring diagram and the requirements of your local building codes. The information is for suggested use ONLY. Check your local codes BEFORE installation. OUTPUT WIEGAND INPUT GATE 1 OUTPUT 2 SDA SCL NO COM NC NO COM NC 1 WIEGAND 2 D1 COM D0 D1 COM D0 INPUT POWER 1 GND 2 GND 12V-24V NORMALLY OPEN COMMON NORMALLY OPEN COMMON NORMALLY CLOSED NOTE: The SDA/SLA Gate input/output shall not be connected in UL applications. PRIMARY RELAY POWER ETHERNET STATUS EOL (End of Line) Resistor (1k ohm) GATE OPERATOR (connect to Aux Closed Limit switch refer to gate operator manual) EXIT GATE OPERATOR Refer to the Gate Operator manual for wiring details. NOTE: For UL installations, only a UL 325 Listed Gate Operator, UL 294 Listed electric door strikes or UL 294 Listed Maglocks may be connected to relay output 1 or 2. AUXILIARY RELAY Low Voltage Power Supply Isolation Relay LIGHT LOAD LINE NEUTRAL OR OR ALARM BYPASS COMMON NORMALLY OPEN *AUXILIARY RELAY MAGLOCK For AC Power: Install a Siemens S10K30MOV (Metal Oxide Varistor) (provided) or equivalent NORMALLY CLOSED Use 18-22 AWG COMMON - + Power for Maglock (Not Provided) DO NOT use the power supply for the controller For DC Power: Install a 1N4005 diode or equivalent

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

Gate Access
INPUT
OUTPUT
WIEGAND
GATE
SDA SCL
OUTPUT
NO COM NC
NO COM NC
1
2
D1 COM D0
D1 COM D0
1
2
WIEGAND
1
GND
2
INPUT
GND 12V-24V
POWER
POWER
ETHERNET
GATE OPERATOR
(connect to Aux
Closed Limit switch -
refer to gate operator
manual)
EOL (End of Line)
Resistor (1k ohm)
STATUS
+
MAGLOCK
Use 18-22 AWG
Power for Maglock
(Not Provided)
DO NOT
use the power
supply for the controller
COMMON
NORMALLY CLOSED
NORMALLY CLOSED
COMMON
*AUXILIARY RELAY
NORMALLY OPEN
ALARM BYPASS
LIGHT
NORMALLY OPEN
COMMON
LOAD
LINE
AUXILIARY RELAY
OR
OR
NEUTRAL
Isolation
Relay
Low
Voltage
Power
Supply
PRIMARY RELAY
GATE OPERATOR
EXIT
NORMALLY OPEN
COMMON
For DC Power:
Install a 1N4005
diode or equivalent
For AC Power:
Install a Siemens S10K30MOV
(Metal Oxide Varistor) (provided)
or equivalent
NOTE:
The SDA/SLA
Gate input/output shall
not be connected in UL
applications.
Not responsible for conflicts between the information listed in
the wiring diagram and the requirements of your local building
codes. The information is for suggested use ONLY. Check your
local codes BEFORE installation.
NOTE
: For UL installations, only a
UL 325 Listed Gate Operator, UL
294 Listed electric door strikes or
UL 294 Listed Maglocks may be
connected to relay output 1 or 2.
Refer to the Gate Operator manual
for wiring details.