LiftMaster 8500W Instructions - English French Spanish

LiftMaster 8500W Manual

LiftMaster 8500W manual content summary:

  • LiftMaster 8500W | Instructions - English French Spanish - Page 1
    battery power BEFORE performing ANY service or maintenance. Before you begin to connect your opener to the network. 1. Disconnect power. 2. Open the front in accordance with the instructions, may cause harmful from the safety reversing sensors, door control, door lock and cable tension monitor from
  • LiftMaster 8500W | Instructions - English French Spanish - Page 2
    cable, the operator light will flash 5 times. Ensure the cable tension monitor is correctly installed (see owner's manual) then follow the steps for Program the Travel. If the garage door opener lights are flashing 10 times during the steps for Program the Travel, the safety reversing sensors are
  • LiftMaster 8500W | Instructions - English French Spanish - Page 3
    garage door. 2. Press the remote control push button to close the door. The door MUST reverse when it makes contact with the board. If the door stops but does not reverse: 1. Review the installation instructions or obstructed). If the garage door opener closes the door when the safety reversing
  • LiftMaster 8500W | Instructions - English French Spanish - Page 4
    button. The garage door opener lights will flash (or two clicks will be heard) when the code has been programmed instructions included with the device or visit LiftMaster.com. Add MyQ serial number to MyQ App To program the Wi-Fi garage door opener to your network, refer to your owner's manual
  • LiftMaster 8500W | Instructions - English French Spanish - Page 5
    de série MyQ pour connecter votre ouvre-porte de garage au réseau. 1. Débrancher l'alimentation électrique 2. pas installé et utilisé conformément aux instructions, peut causer des interférences nuisibles aux télécommande et de l'émetteur à code (voir la page 4). 12. Utiliser l'application MyQ pour ajouter le
  • LiftMaster 8500W | Instructions - English French Spanish - Page 6
    d'inversion de sécurité. • Après avoir effectué QUELQUE réglage que ce soit, on DOIT faire l'essai du système d'inversion de sécurité. La porte de garage DOIT remonter au contact d'un objet d'une hauteur de 3,8 cm (1-1/2 po) (ou un 2 x 4 posé à plat) du sol. Pour prévenir les dommages aux véhicules
  • LiftMaster 8500W | Instructions - English French Spanish - Page 7
    arrête sa course, mais ne l'inverse pas : 1. Revoir les instructions d'installation fournies pour s'assurer que toutes les étapes ont été suivies. avertit que le détecteur est mal aligné ou obstrué). Si l'ouvre-porte de garage ferme la porte lorsque le capteur d'inversion de sécurité est obstrué (et
  • LiftMaster 8500W | Instructions - English French Spanish - Page 8
    l'étape 2 jusqu'à ce que l'éclairage de l'ouvre-porte de garage clignote ou que deux clics se fassent entendre. Pour programmer d'autres types de télécommandes ou d'émetteurs à code, voir les instructions fournies avec l'appareil ou aller à LiftMaster.com. Pince de pare-soleil Ajouter un numéro de
  • LiftMaster 8500W | Instructions - English French Spanish - Page 9
    Tarjeta Lógica Modelo 050DCRJWF Para evitar la posibilidad de LESIONES GRAVES o INCLUSO LA MUERTE: • Desconecte TODA la corriente eléctrica y de la batería ANTES de realizar cualquier servicio o mantenimiento. Antes de empezar. Su nuevo número de serie de MyQ® está ubicado en la etiqueta de
  • LiftMaster 8500W | Instructions - English French Spanish - Page 10
    en el cable, la luz del operador parpadeará 5 veces. Asegúrese de que el monitor de tensión en el cable esté correctamente instalado (consulte el manual del propietario) luego siga los pasos para programar el desplazamiento. Si las luces del abre-puertas de garaje parpadean 10 veces durante la
  • LiftMaster 8500W | Instructions - English French Spanish - Page 11
    Ajustes Prueba del sistema de reversa de seguridad Prueba 1. Con la puerta completamente abierta, coloque una tabla de 3.8 cm (1 1/2 de pulg.) de altura (o de 5 x 10 cm [2 x 4 pulg.] acostada en el piso), centrada abajo de la puerta del garaje. 2. Opere la puerta en la dirección hacia abajo. La
  • LiftMaster 8500W | Instructions - English French Spanish - Page 12
    digitales, consulte las instrucciones que se incluyen con el dispositivo o visite LiftMaster.com. Agregar el número de serie de MyQ a la aplicación el abre-puertas de garaje con Wi-Fi a su red, consulte el manual de usuario. para continuar 4. OU PIN 4."chasqui"dcoh"asquido" Botón APRENDIZAJE
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

1
A
B
B
B
C
E
D
F
Logic Board
Model 050DCRJWF
WARNING:
This product can expose you to chemicals including
lead, which are known to the State of California to cause cancer or
birth defects or other reproductive harm. For more information go
to
www.P65Warnings.ca.gov
To prevent possible SERIOUS INJURY or DEATH:
Disconnect ALL electric and battery power BEFORE performing ANY
service or maintenance.
To prevent damage to the receiver/logic board, DO NOT touch printed
circuit board of replacement receiver/logic board during installation.
ALWAYS wear protective gloves and eye protection when changing the
battery or working around the battery compartment.
NOTICE:
This device complies with Part 15 of the FCC rules and Industry Canada’s license-
exempt RSSs. Operation is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
This device must be installed to ensure a minimum 20 cm (8 in.) distance is maintained between
users/bystanders and device.
This device has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC rules and Industry Canada ICES standard. These limits are
designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
Before you begin.
Your new MyQ
®
serial number is located on the
replacement label with your replacement logic board. You will need this new MyQ
serial number to connect your opener to the network.
1.
Disconnect power.
2.
Open the front panel
(A)
.
3.
Remove the battery cover.
Disconnect the battery. Remove
the battery and set aside
(B)
.
4.
Disconnect the wires coming
from the safety reversing sensors,
door control, door lock and cable
tension monitor from the logic
board
(C)
.
5.
Remove the logic board cover
(D)
.
6.
Disconnect all the wiring harnesses
from the logic board
(E)
.
7.
Remove the four screws securing
the logic board, remove the logic
board
(F)
, and discard.
8.
Install the new logic board and
connect the wiring harnesses.
Route the antenna through the
channel in the cover.
9.
Adhere the new MyQ serial
number label over the original
label on the logic board cover.
10.
Reprogram the travel and test the
safety reversal system (see pages
2 and 3).
11.
Program all remote controls and
keyless entries (see page 4).
12.
Use the MyQ app to add the
new MyQ serial number to your
account.