KitchenAid WVW53UC0FS Dimension Guide - Page 2
For Non-Vented Recirculating Installations, Calculating Vent System Length, Example Vent System - hood
View all KitchenAid WVW53UC0FS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
For Non-Vented (Recirculating) Installations If it is not possible to vent cooking fumes and vapors to the outside, the hood can be used in the non-vented (recirculating) version, using a Recirculation Kit (which includes charcoal filters and a deflector). To order, see the "Assistance or Service" section. Roof Venting Wall Venting Non-Vented (Recirculating) Example Vent System 90 elbow 6 ft (1.8 m) 2 ft (0.6 m) Wall cap The following example falls within the maximum recommended vent length of 35 ft (10.7 m). 1 - 90° Elbow 1 - Wall cap 8 ft (2.4 m) straight Length of system = 5 ft (1.5 m) = 0 ft (0 m) = 8 ft (2.4 m) = 13 ft (3.9 m) A. Roof cap B. 6" (15.2 cm) round vent A. Wall cap B. 6" (15.2 cm) round vent A. Deflector B. 6" (15.2 cm) round vent Calculating Vent System Length To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system. Vent Piece 45° elbow 6" (15.2 cm) Round 2.5 ft (0.8 m) 90° elbow 5 ft (1.5 m) Maximum equivalent vent length is 35 ft (10.7 m). Because Whirlpool Corporation includes a continues commitment to improve our products, we reserve the right to change materials and specifications without notice. Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice. Page 2 of 2 Ref. W10836385B 05/09/2016