CALCULATING VENT SYSTEM LENGTH, 17.8 cm Round Vent System, Example vent system, Maximum Recommended

Page 2 highlights

CALCULATING VENT SYSTEM LENGTH To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system. 7" (17.8 cm) Round Vent System Vent Piece Round 45° elbow 2.5 ft (0.8 m) 90° elbow 5.0 ft (1.5 m) 7" (17.8 cm) wall cap 0.0 ft (0.0 m) 3¹⁄4" x 10" (8.3 cm x 25.4 cm) to 7" (17.8 cm) 4.5 ft (1.4 m) Example vent system 3¼" x 10" (8.3 x 25.4 cm) elbow 6 ft (1.8 m) 2 ft (0.6 m) Maximum Recommended Length 1 - 90° elbow 8 ft (2.4 m) straight 1 - wall cap Length of 3¹⁄4" x 10" (8.3 cm x 25.4 cm) system Wall cap = 35 ft (10.7 m) = 5.0 ft (1.5 m) = 8.0 ft (2.4 m) = 0.0 ft (0.0 m) = 13.0 ft (3.9 m) 3¹⁄4" x 10" (8.3 cm x 25.4 cm) to 7" (17.8 cm) 90° elbow 5.0 ft (1.5 m) Example vent system 7" (17.8 cm) round 90˚ elbow 6 ft (1.8 m) Wall cap 2 ft (0.6 m) Maximum Recommended Length 1 - 90° elbow 1 - wall cap 8 ft (2.4 m) straight Length of 7" (17.8 cm) system = 50 ft (15.2 m) = 5.0 ft (1.5 m) = 0.0 ft (0.0 m) = 8.0 ft (2.4 m) = 13.0 ft (3.9 m) 3¹⁄4" x 10" (8.3 cm x 25.4 cm) Vent System Vent Piece 3¹⁄4" x 10" (8.3 cm x 25.4 cm) 90° elbow 5.0 ft (1.5 m) 3¹⁄4" x 10" (8.3 cm x 25.4 cm) flat 12.0 ft elbow (3.7 m) 3¹⁄4" x 10" (8.3 cm x 25.4 cm) wall 0.0 ft cap (0.0 m) Because Whirlpool Corporation includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice. Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice. Page 2 of 2 Ref. W10907132A 01/05/2017

  • 1
  • 2

Because Whirlpool Corporation includes a continuous commitment to improve our
products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10907132A
01/05/2017
Page 2 of 2
CALCULATING VENT SYSTEM LENGTH
To calculate the length of the system you need, add the equivalent feet
(meters) for each vent piece used in the system.
7" (17.8 cm) Round Vent System
Vent Piece
Round
45° elbow
2.5 ft
(0.8 m)
90° elbow
5.0 ft
(1.5 m)
7" (17.8 cm) wall cap
0.0 ft
(0.0 m)
3¹⁄
4
" x 10" (8.3 cm x 25.4 cm) to
7" (17.8 cm)
4.5 ft
(1.4 m)
3¹⁄
4
" x 10" (8.3 cm x 25.4 cm) to
7" (17.8 cm) 90° elbow
5.0 ft
(1.5 m)
Example vent system
Maximum Recommended Length
= 50 ft (15.2 m)
1 - 90° elbow
= 5.0 ft (1.5 m)
1 - wall cap
= 0.0 ft (0.0 m)
8 ft (2.4 m) straight
= 8.0 ft (2.4 m)
Length of 7" (17.8 cm) system
= 13.0 ft (3.9 m)
3¹⁄
4
" x 10" (8.3 cm x 25.4 cm) Vent System
Vent Piece
3¹⁄
4
" x 10" (8.3 cm x 25.4 cm) 90°
elbow
5.0 ft
(1.5 m)
3¹⁄
4
" x 10" (8.3 cm x 25.4 cm) flat
elbow
12.0 ft
(3.7 m)
3¹⁄
4
" x 10" (8.3 cm x 25.4 cm) wall
cap
0.0 ft
(0.0 m)
Example vent system
Maximum Recommended Length
= 35 ft (10.7 m)
1 - 90° elbow
= 5.0 ft (1.5 m)
8 ft (2.4 m) straight
= 8.0 ft (2.4 m)
1 - wall cap
= 0.0 ft (0.0 m)
Length of 3¹⁄
4
" x 10" (8.3 cm x 25.4 cm)
system
= 13.0 ft (3.9 m)
Wall cap
7" (17.8 cm) round
90˚ elbow
2 ft (0.6 m)
6 ft (1.8 m)
Wall cap
3
¼
" x 10"
(8.3 x 25.4 cm)
elbow
2 ft
(0.6 m)
6 ft (1.8 m)