KitchenAid UXT4230AYB Use & Care Guide - Page 10
Connector, Power Supply Cable Installation
![]() |
View all KitchenAid UXT4230AYB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
NOTE: The 7" (17.8 cm) round vent mounting plate and 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular vent damper can be installed up to 1" (2.5 cm) on either side of the hood center to accommodate off center ductwork. B A C D B A. Vertical damper B. 3.5 x 9.5 mm screws C. Vent knockouts D. Horizontal damper ■ If a vent damper is installed with a wall cap with damper, check that they do not interfere with each other. Remove the vent connector damper flap if they interfere. ■ Non-vented (recirculating) installations - No vent attachments. Removal of the recirculation cover plate is required. Remove the two screws from the recirculation cover plate and remove. A B 2. Slide retainer wire to the side to allow one end of retainer wire to come out of the damper flap wire guide and plastic end cap. 3. Lift end of retainer wire and slide it out of the other damper flap wire guide and plastic end cap to remove. 4. Push the small end of the plastic end caps out of vent connector housing. 5. Lift the damper flap out of the vent connector housing. 6. Remove the foam from the stop tab. 7. Bend the stop tabs so they are flush with the damper side walls. 8. Discard the retainer wire, plastic end caps, damper flap and the foam. Power Supply Cable Installation 1. For direct wire installations, run the home power supply cable according to the National Electric Code or CSA standards and local codes and ordinances. There must be enough wiring from the fused disconnect (or circuit breaker) box to make the connection in the hood electrical terminal box. For optional power supply cord kit installations, follow the instructions in the "Make Electrical Connection" section. NOTE: Do not reconnect power until the installation is complete. 2. Remove the screw from the terminal box cover. Remove terminal box cover and set aside. A B A. Recirculation cover plate B. Screws Damper Flap Removal for 3¼" x 10" (8.3 x 25.4 cm) Vent Connector 1. Bend retainer wire out of damper flap catch tab. C A. Terminal box cover B. Screw 3. Remove the power supply knockout from the top or rear of the vent hood (depending on the incoming location of your home power supply cable), and install a UL listed or CSA approved ¹⁄₂" strain relief. A B A HG F A. Retainer wire B. Damper flap wire guide C. Plastic end caps D. Stop tabs E E. Vent connector housing F. Foam G. Damper flap catch tab H. Damper flap 10 A. Power supply knockout 4. Using 2 or more people, lift the hood into final position. Feed enough electrical wire through the ½" UL listed or CSA D approved strain relief to make connections in the terminal box. Tighten the strain relief screws. 5. Position the range hood so that the large end of the keyhole slots are over the mounting screws. Then push the hood toward the wall so that the screws are in the neck of the slots. Tighten the mounting screws, making sure the screws are in the narrow neck of slots. 6. Connect ventwork to hood. Seal joints with vent clamps or duct tape to make secure and airtight. 7. Check that back draft dampers work properly.
![](/manual_guide/products/kitchenaid-uxt4230ays-use-care-guide-76c4144/10.png)