Make Electrical Connection WARNING 4. Run the power supply cable or power cord kit (see the "Accessories" section for information on ordering) through strain relief, into terminal box. A B Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. 1. Disconnect power. 2. Remove the terminal box cover. 3. Remove the knockout in the terminal box cover and install a UL listed or CSA approved ¹⁄₂" strain relief. A B C D E F A. Power supply cable or power cord kit B. UL listed or CSA approved strain relief C. Black wires D. UL listed wire connectors E. White wires F. Green (or bare) and yellowgreen ground wires 5. Use UL listed wire connectors and connect the black wires (C) together. 6. Use UL listed wire connectors and connect the white wires (E) together. WARNING A. Knockout B. Terminal box cover Electrical Shock Hazard Electrically ground blower. Connect ground wire to green and yellow ground wire in terminal box. Failure to do so can result in death or electrical shock. 7. Connect green (or bare) ground wire from the power supply or power cord kit to yellow-green ground wire (F) in terminal box using UL listed wire connectors. 8. Tighten the strain relief screw. 9. Install the terminal box cover. 10. Check that all light bulbs are secure in their sockets. 11. Reconnect power. 9