Invacare TDXSP2 Owners Manual 3 - Page 102
LiNX Wireless Functions
View all Invacare TDXSP2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 102 highlights
LiNX® Control System homes, vocational settings and health care facilities. Across these environments, there are numerous different items of both medical and non-medical equipment that also operate wirelessly. 9.3 LiNX Wireless Functions The LiNX control system functions that use Bluetooth include: • Mouse mover-controls the mouse cursor on a PC, laptop or other portable device. • Remote diagnostics-provides status information of the powered wheelchair (battery status, fault conditions etc.). • Configuration-by a trained provider, dealer, therapist or clinician using the programming and diagnostic tools, configures the LiNX control system. 9.3.1 Mouse Mover The system is able to operate as a standard wireless PC mouse where the joystick or other user input can be used to move the cursor on the screen on a PC, laptop or other similar device. Buttons within the system can also be used to emulate a "left click" and "right click". When in Mouse Mover mode, the wheelchair is stationary and unable to drive. 9.3.2 Remote Diagnostics The system transmits wheelchair-specific diagnostic information to an Apple iOS device. This information helps with the technical support of the wheelchair. The information provides the status of the wheelchair electronics, including: 102 • The state of charge of the battery, • Active and historical fault data, • Wheelchair driving time, and • Information about the modules attached to the wheelchair (e.g. module serial numbers). The information updates once every 12 hours (when connected), or whenever requested by an application on the iOS device. Note that the wheelchair may be in motion at the time of transmission. 9.3.3 Configuration The LiNX Programming and Diagnostic (P&D) tools use Bluetooth to communicate with the LiNX control system via the LiNX Access Key (LAK). The LAK is a standalone device that plugs into a remote module. A system cannot be configured without using the LAK and only manufacturers, trained providers, dealers, therapists or clinicians have access to the LAK. This means that end users, their friends, relatives or caregivers cannot change the configuration. There are two levels of access: • Manufacturer (or OEM) and • Distributor (provider/clinician). The levels of access permit the following: • LAK Manufacturer Level With this level, the manufacturer sets the system's default parameters to suit a particular wheelchair. • LAK Distributor Level With this level, a subset of the system's parameters is configured by trained providers, dealers, clinicians or therapists. Critical parameters are limited within a predetermined range as set by the manufacturer. 60101833-A