Motion Detector Walk Test, IMPORTANT
View all Honeywell RCA902 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
RCA902A Motion Detector Walk Test IMPORTANT: Before commencing walk test ensure the LED indicator behind the detector lens is not flashing continuously. If it is wait until the detector has completed its warm-up cycle and the flashing stops. Configure the detector for walk testing according to the selected Day or Night operating mode as follows: 1) Set the TIME control fully counter-clockwise to its minimum setting. 2) If the detector is set to DAY operation (for use with a chime), adjust the DUSK control fully counter-clockwise to its minimum setting. If the detector is set to NIGHT operation (for use with lighting) adjust the DUSK control fully clockwise to its maximum setting. 69-2157EFS_C.indd 9 DUSK CONTROL SETTING FOR NIGHT OPERATION DUSK CONTROL SETTING FOR DAY OPERATION Fig. 5 TIME CONTROL M27297 9 69-2157EFS-05 9/22/2008 11:54:00 AM