Honeywell 4600RSF051C User Guide - Page 97
Codabar, <Default All Codabar Settings>
![]() |
View all Honeywell 4600RSF051C manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 97 highlights
Codabar Codabar * On Off Codabar Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the barcode. You may either transmit, or not transmit Start/Stop characters. Default = Don't Transmit. Transmit * Don't Transmit Codabar Check Character Codabar check characters are created using different "modulos." You can program the imager to read only Codabar barcodes with Modulo 16 check characters. Default = No Check Character. No Check Character indicates that the imager reads and transmits barcode data with or without a check character. When Check Character is set to Validate and Transmit, the imager will only read Codabar barcodes printed with a check character, and will transmit this character at the end of the scanned data. 7 - 3
![](/manual_guide/products/honeywell-4600rsf051ce-user-guide-cd48244/97.png)