Hitachi CPX467 User Manual - Page 22

Correcting the keystone distortions

Page 22 highlights

Operating Correcting the keystone distortions KEYSTONE button 1. Press KEYSTONE button on the remote control. A dialog will appear on the screen to aid you in correcting the distortion. 2. Use the ▲/▼ cursor buttons to select AUTO, MANUAL or PERFECT FIT operation, and press the ► button to perform the following. MY SOURCE/ VIDEO COMPUTER DOC.CAMERA ASPECT AUTO SEARCH BLANK MAGNIFY FREEZE PAGE VOLUME UP ON 㧗 DOWN OFF ࡯ KEYSTONE MY BUTTON MUTE 1 2 (1) AUTO executes automatic vertical keystone correction. POSITION MENU (2) MANUAL displays a dialog for keystone correction. Use the ◄/► cursor buttons to select the direction to correct ( or ) then use the ▲/▼ buttons for adjustment. ESC ENTER RESET (3) PERFECT FIT displays a dialog for the shape adjustment of the projected image in each of the corners. 1) Choose the corner to adjust using the buttons and press the ENTER or INPUT button. 2) Use the buttons to adjust the position of the corner. Press the ENTER or INPUT button to exit the adjustment of the corner. 3) To adjust another corner, follow the same procedure from 1) above. To reset the adjustment of all the corners, select RESET using the ▲/▼ buttons and press the ENTER or INPUT button. To close the dialog and complete this operation, press KEYSTONE button again. Even if you do not do anything, the dialog will automatically disappear after a few seconds. ● While the positions of the corners are adjusted with PERFECT FIT, keystone adjustment feature is unavailable. To correct the keystone distortion, reset the adjustment of all the corners. ● The adjustable range of this function will vary among inputs. For some input, this function may not work well. ● When V:INVERT or H&V:INVERT is selected to the MIRROR item in the SETUP menu, if the projector screen is inclined or angled downward, automatic vertical keystone correction may not work correctly. ● When the zoom adjustment is set to the TELE (telephoto focus), this function may be excessive. This function should be used when the zoom adjustment is set to the full WIDE (wide-angle focus) whenever possible. ● When the projector is placed on the level (about ±3°), the automatic keystone distortion correction may not work. ● When the projector is inclined to near ±30 degree or over, this function may not work well. ● This function will be unavailable when Transition Detector is on (53). 22

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

22
Operating
1.
Press
KEYSTONE
button on the remote
control. A dialog will appear on the screen to
aid you in correcting the distortion.
Correcting the keystone distortions
2.
Use the ▲/▼ cursor buttons to select AUTO, MANUAL or
PERFECT FIT operation, and press the ► button to perform
the following.
(1) AUTO executes automatic vertical keystone correction.
(2) MANUAL displays a dialog for keystone correction.
Use the ◄/► cursor buttons to select the direction to
correct (
or
) then use the ▲/▼ buttons for adjustment.
(3) PERFECT FIT displays a dialog for the shape adjustment of the
projected image in each of the corners.
1) Choose the corner to adjust using the ▲/▼/◄/► buttons and
press the
ENTER
or
INPUT
button.
2) Use the ▲/▼/◄/► buttons to adjust the position of
the corner.
Press the
ENTER
or
INPUT
button to exit the
adjustment of the corner.
3) To adjust another corner, follow the same procedure
from 1) above.
To reset the adjustment of all the corners, select
RESET using the ▲/▼ buttons and press the
ENTER
or
INPUT
button.
To close the dialog and complete this operation, press
KEYSTONE
button again.
Even if you do not do anything, the dialog will automatically disappear after a few
seconds.
● While the positions of the corners are adjusted with PERFECT FIT, keystone
adjustment feature is unavailable. To correct the keystone distortion, reset the
adjustment of all the corners.
● The adjustable range of this function will vary among inputs. For some input, this
function may not work well.
● When V:INVERT or H&V:INVERT is selected to the MIRROR item in the SETUP
menu, if the projector screen is inclined or angled downward, automatic vertical
keystone correction may not work correctly.
● When the zoom adjustment is set to the TELE (telephoto focus), this function may
be excessive. This function should be used when the zoom adjustment is set to
the full WIDE (wide-angle focus) whenever possible.
● When the projector is placed on the level (about ±3°), the automatic keystone
distortion correction may not work.
● When the projector is inclined to near ±30 degree or over, this function may not
work well.
● This function will be unavailable when Transition Detector is on (
53
).
KEYSTONE
button
VIDEO
DOC.CAMERA
KEYSTONE
ASPECT
SEARCH
BLANK
MUTE
MY BUTTON
1
2
COMPUTER
MY SOURCE/
AUTO
MAGNIFY
PAGE
UP
VOLUME
DOWN
ON
OFF
FREEZE