Hitachi CP-X4021N Network Guide - Page 54

Apply], Filter Error, Lamp Time Alarm, Filter Time Alarm

Page 54 highlights

3. Web Control 3.6 Alert Settings (Continued) The Alert Items are shown below. Item Alarm Time SNMP Trap Send Mail Mail Subject Mail Text Description Configures the time to alert. (Only Lamp Time Alarm and Filter Time Alarm.) Click the [Enable] check box to enable SNMP Trap alerts. Click the [Enable] check box to enable e-mail alerts. (Except Cold Start and Authentication Failure.) Configures the subject line of the e-mail to be sent. The length of the subject line can be up to 100 alphanumeric characters. (Except Cold Start and Authentication Failure.) Configures the text of the e-mail to be sent. The length of the text can be up to 1024 alphanumeric characters, but if you are using some of special characters below the length may be shorter. Special characters and space (Except Cold Start and Authentication Failure.) Click the [Apply] button to save the settings. NOTE • The trigger of Filter Error e-mail is depending on the FILTER MESSAGE setting in the SERVICE item of the OPTION menu which defines the period until the filter message is displayed on the projector screen. An e-mail will be sent when the usage time of the filter exceeds the time limit that is set. No notification e-mail will be sent if the FILTER MESSAGE is set to TURN OFF. ( OPTION menu in the User's Manual - Operating Guide) • Lamp Time Alarm is defined as a threshold for e-mail notification (reminder) of the lamp timer. When the lamp hour exceeds this threshold that is configured through the Web page, the e-mail will be sent out. • Filter Time Alarm is defined as a threshold for e-mail notification (reminder) of the filter time. When the filter hour exceeds this threshold that is configured in the Web page, the e-mail will be sent out. 54

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92

54
The Alert Items are shown below.
Item
Description
Alarm Time
Configures the time to alert.
(Only
Lamp Time Alarm
and
Filter Time Alarm
.)
SNMP Trap
Click the
[Enable]
check box to enable SNMP Trap alerts.
Send Mail
Click the
[Enable]
check box to enable e-mail alerts.
(Except
Cold Start
and
Authentication Failure
.)
Mail Subject
Configures the subject line of the e-mail to be sent.
The length of the subject line can be up to 100 alphanumeric
characters.
(Except
Cold Start
and
Authentication Failure
.)
Mail Text
Configures the text of the e-mail to be sent.
The length of the text can be up to 1024 alphanumeric
characters, but if you are using some of special characters
below the length may be shorter.
Special characters
" ' : & , % \
and space
(Except
Cold Start
and
Authentication Failure
.)
Click the
[Apply]
button to save the settings.
• The trigger of
Filter Error
e-mail is depending on the FILTER
MESSAGE setting in the SERVICE item of the OPTION menu which defines
the period until the filter message is displayed on the projector screen. An
e-mail will be sent when the usage time of the filter exceeds the time limit that is
set. No notification e-mail will be sent if the FILTER MESSAGE is set to TURN
OFF. (
²
OPTION menu in the User’s Manual – Operating Guide
)
Lamp Time Alarm
is defined as a threshold for e-mail notification (reminder)
of the lamp timer. When the lamp hour exceeds this threshold that is configured
through the Web page, the e-mail will be sent out.
Filter Time Alarm
is defined as a threshold for e-mail notification (reminder)
of the filter time. When the filter hour exceeds this threshold that is configured
in the Web page, the e-mail will be sent out.
NOTE
3.6 Alert Settings (Continued)
3. Web Control