HP StorageWorks 7110 Appendix A. Disk Array Controller Log - Page 14
x13a, 0x13b, 0x13c, 0x13d, 0x13e, 0x13f
View all HP StorageWorks 7110 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
FC-SCSI Interface SpecificationDescribes the IceCube SCSI interface. Targetted as part of OEM manual.Disk Array Con Error! No text of specified style in document. Event Number (dec/hex) Event Name Predictive Maintenance Implication Suspected Components Description Logged? Mfg Fail? 314/0x13a 315/0x13b 316/0x13c 317/0x13d 318/0x13e 319/0x13f 320/0x140 321/0x141 322/0x142 323/0x143 324/0x144 325/0x145 326/0x146 327/0x147 328/0x148 used. Drive Missing At Power On Y Ignore unless no Disk Drive, N This error code indicates that a drive was discovered Operator activity Controller, to be missing during a power on or reset. This event Back End FC occurs for volume set members only. The device Link number of the drive removed appears in this change record. A device number consisting of the controller serial number followed by a 0 indicates that the device number has not yet been assigned. RAM Image Upload Failed Y Single Disk Drives, N The subsystem was unable to upload a usable disk Occurrance Controller, copy of NVRAM during startup. System state is Back End FC NO_MAPS. Link Old Cache Configuration Used Y Ignore - See None N Write data found in the uploaded NVRAM image errors associated blocked a requested transition to a new cache with shut down configuration; the previous configuration is being used. To get to the new configuration, get cache flushed and do another upload. Incompatible RAM Image Y Ignore - Operator None N This is an error detected by the startupSystem when Content error the current RAM config is not compatible with the RAM config of the NVRAM disk image. This is similar to except that not enough physical RAM space is not the problem but rather a different mapping of NVRAM in the disk image that cannot be supported by the current config (i.e., the image supports 8G drives but the current config does not). A new VS is created. System state is NO_MAPS. To use the disk image the current config must be updated to the disk config. Disk Interface Underrun Event Y Single Disk, N An attached device sent/received less data than Occurrance not controller, disk expected. with other entries interface Disk Interface Overrun Event Y Single Disk, N An attached disk sent/received more data than Occurrance not controller, disk expected. with other entries interface Disk Interface Timeout Event Y > 2 occurrances Disk, N A command to an attached disk did not complete per hot plug controller, disk within the allotted time. insert or removal interface Controller ECC Miscorrection Y Single SIMM, N This error code indicates that the system Occurrance Controller experienced a correctable error which was mostlikly misscorrected. Controller Data Bus Y Single Controller N This error code indicates that the system Microprocessor Access Error Occurrance experienced a uP access error without the needed other qualifiers. Microprocessor access errors should only occur in conjunction with correctable or uncorrectable memory errors, or with parity errors. If no other condition is present this event is reported to indicate the malfunction. Incompatible Address Table In Y Ignore - Operator None N This error occurs when NVRAM (SIMM(S)) is RAM Image error removed, forcing the Time Stamp Table to shrink, or the image to be reloaded has an invalid size. Once NVRAM is added and the Table is expanded, it cannot shrink. Non-Volatile Memory Y Ignore unless no SDRAM N This message is logged when NV-SDRAM is found Initialized operator activity DIMM, to be invalid at boot and must be initialized. This Controller should not cause concern if memory was purposely invalidated or a new board or new memory has just been installed. Battery Failed Discharge Test Y Single Battery N This error code indicates that a battery has failed the Occurrance long discharge test. This test occurs following power on and every 30 days thereafter. The test takes about 36 hours to complete. Replace Batteries. Fan Failed Y Single Fan, Controller, N This error code indicates that a fan has failed. Occurrance Backplane Power Supply Failed Y Single Power Supply, N This error code indicates that a power supply has Occurrance Controller, failed. Backplane Power Down Due To Fan Y Single Fans, N This error code indicates that the Background