HP Scitex FB10000 Geffen TS Error 67014 - Page 5
The B&R module is faulty
View all HP Scitex FB10000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
Error ID: 67014: Safety - Unloader door is open FB10000 Error Messages Troubleshooting The B&R module is faulty 1. Measure 2TBM-10(3) and 2TBM-12(3) voltage via 24V_gnd (24V_0). You should get 8-20V this means that the entire route is ok and that the module is faulty. 2. As a last check before replacing the module, ensure that the wires between the pulse outputs and the 2TBM distribution block are properly attached. w ch Note: Each B&R Safety module is comprised of three parts: Base, BU (Bus Unit), and two (12 pins) terminal blocks. Replacing a faulty B&R module means replacing only its BU, which is the "heart" of the module. 3. Before replacing a B&R module, turn the machine power OFF. 4. Release the two TBs from the faulty BU module together with their wires, as shown in the figure below. 5. Pull the BU out of the module base and replace it by a new module BU module. 6. Plug the two TBs back into the module BU until you hear a click. Upon turning on the machine, the R/E led will blink green single pulse, signaling that it has detected the new module. 5