HP AJ732A Cisco MDS 9200 Series Hardware Installation Guide (OL-16188-01, Apri - Page 121
Technical Specifications, Switch Specifications
UPC - 883585789481
View all HP AJ732A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 121 highlights
Send documentation comments to [email protected] B A P P E N D I X Technical Specifications This appendix includes the following sections: • Switch Specifications, page B-1 • Module Specifications, page B-2 • Power Specifications, page B-4 • X2 Transceiver Specifications, page B-6 • SFP Transceiver Specifications, page B-9 Note Specifications for cables and connectors are provided in Appendix C, "Cable and Port Specifications." Switch Specifications This section provides switch specifications for theCisco MDS 9200 Series. Table B-1 lists the environmental specifications for the Cisco MDS 9200 Series. Table B-1 Environmental Specifications for the Cisco MDS 9200 Series Description Specification Temperature, certified for operation 32 to 104°F (0 to 40°C) Temperature, designed and tested for operation 32 to 130°F (0 to 55°C) Temperature, ambient nonoperating and storage -40 to 158°F (-40 to 70°C) Humidity (RH), ambient (noncondensing) operating 10 to 90% Humidity (RH), ambient (noncondensing) nonoperating and storage 5 to 95% Altitude, certified for operation 0 to 6500 ft (0 to 2000 m) Altitude, designed and tested for operation -200 to 10000 ft (-60 to 3000 m) Noise levels 70 dB OL-16188-01 Cisco MDS 9200 Series Hardware Installation Guide B-1