HP AJ732A Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.3 - Page 35
Open Caveats, After creating SANTap Control Virtual Targets CVTs or SANTap Data Virtual Targets
UPC - 883585789481
View all HP AJ732A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 35 highlights
Caveats Send documentation comments to [email protected] • CSCso83333 Symptom: System utilization might be incorrectly displayed after the active supervisor is up for about 497 days. This is a cosmetic issue and there is no functional impact because of this. Workaround: This issue is resolved. • CSCsw87910 Symptom: When running Cisco MDS Release SAN-OS 3.3(2) with DPVM enabled, if a link flaps for a end device with DPVM enabled, you might see the following message in the output of the show logging log command: %DPVM-3-PSS_ERR: Failed to update Login info NPV contextpwwn: 50:00:00:00:aa:99:ee:44, syserr = no such pss key Workaround: This issue is resolved. • CSCta32005 Symptom: Upon receiving an OLS when a link went down, the OLS counter was not incremented. Workaround: This issue is resolved. • CSCsz22811 Symptom: Compression throughput on the MSM-18/4 module has been improved. Workaround: This issue is resolved. Open Caveats • CSCsr85709 Symptom: Under certain conditions, the port manager can take a long time to respond to a port configuration, which can trigger a set-port-configuration failure. If this occurs, then the FCIP tunnel will not come up and will stay in a disabled state. Workaround: Enter a shut command, followed by a no shut command on the FCIP interface at either end of the FCIP tunnel. • CSCsk35725 Symptom: Fabric Manager takes 2 to 3 minutes to bring up the DMM job creation wizard in a setup with 25 switches, 400 enclosures, and 2400 entries in the name server. Workaround: None. • CSCso49196 Symptom: During an upgrade from SAN-OS Release 3.2(3a) to Release 3.3(1a), when a switchover occurs to the Supervisor running Release 3.3(1a), Cisco SME traffic flows for hosts that are not connected locally to the switch that is getting upgraded, may get flapped for a very short time. This can also occur during a switchover to a Supervisor running Release 3.3(1a). Workaround: None. • CSCsq20408 Symptom: After creating SANTap Control Virtual Targets (CVTs) or SANTap Data Virtual Targets (DVTs), the running-configuration and the startup-configuration are not synchronized. Output from the show startup-config command will be different from the output of the show running-config and the startup configuration will not display SANTap configuration information. OL-14116-12 Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.3(4) 35